Electrochemical Sensors (4 Series)

SGX electrochemical sensors are a type of fuel cell. These sensors detect gases by producing a chemical reaction between the gas and oxygen contained in the sensor. The reaction produces a small current, which is proportional to the concentration of the gas present.

Notify me on updates of this product 

Availability: Commercially Available

2 Hanbury Rd
Chelmsford, Essex, CM1 3 AE
UK
Manufacturer
SGX Sensortech (IS) Ltd
Product Name
Electrochemical Sensors (4 Series)
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection ;
Application
Emergency Response; Gas Analysis;
Equipment Type
Sensor
Product Synopsis
SGX electrochemical sensors are a type of fuel cell. These sensors detect gases by producing a chemical reaction between the gas and oxygen contained in the sensor. The reaction produces a small current, which is proportional to the concentration of the gas present.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
0.79 x 0.87 in (20 x 22 mm)
Weight
<1 lb.; .2 oz (6 g)
Power Requirements
AC/DC Line Power; Gas Sensor Evaluation Kit uses input voltage of 90 - 264 V AC.
Transportability
Pocket Size
Ruggedness
None
Operating Conditions
-20 to 50°C (-4 to 122°F), 15 – 95% RH. 90 – 110 kPa (pressure) Temperature and humidity requirements may change, depending on the sensor. The sensor data sheets include environmental requirements.
Calibration Schedule
3 month, when using gas sensor evaluation kit and depending on environmental conditions. Bump testing is recommended before each use
Available Accessories
$350 for Evaluation Kit
Data Analysis Support Equipment
Computer with Pentium IV and Windows software; SGX data logging and control software for use on a PC containing Windows XP, Vista, or Windows 7
Communications Interface
Yes
Shelf Life
<5 years; 2 years
Unit Cost
$48.20
Other Chemical Targets
Sensor are available to measure: Chlorine Dioxide, Ethylene Oxide, Hydrogen Sulfide, Hydrogen, Phosphine, Nitrogen Dioxide, Sulfur Dioxide, Carbon Monoxide, Nitric Oxide, Chlorine Dioxide, Oxygen
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm; %
Known Interferents/Inhibitors
The levels of cross-sensitivity vary between sensors and are detailed in each sensor datasheet. Changes in the ambient temperature will affect both the zero signal of the sensor and the net sensitivity to the target gas.
Response Time (Sample Application To Output)
<1 minute; 30 seconds
Alarm Capability
4 configurable alarm outputs when used with the gas sensor evaluation kit
Software Control
PC
Training Required
>1 week training
Manuals Available
Yes
Warranties
Yes
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: