TLV Panther
TLV Panther uses a Photoionization Detector (PID) for the detection of volatile organic compounds (VOCs) such as benzene, toluene, etc. The units are microprocessor controlled, and three alarm setpoints are provided for each gas, as well as audible and visual indications if any of these alarm limits are exceeded. The kit includes a built-in sample pump, sample wand, and carrying case. Datalogging can be included as an option.
Availability: Commercially Available
Manufacturer |
| International Sensor Technology |
Product Name |
| TLV Panther |
Detection Category |
| Chemical |
Detection Principle |
| Molecular Spectroscopy; Sensors; |
Detection Method |
| Photoionization Detection; Electrochemical Detection; |
Application |
| Emergency Response; Gas Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| TLV Panther uses a Photoionization Detector (PID) for the detection of volatile organic compounds (VOCs) such as benzene, toluene, etc. The units are microprocessor controlled, and three alarm setpoints are provided for each gas, as well as audible and visual indications if any of these alarm limits are exceeded. The kit includes a built-in sample pump, sample wand, and carrying case. Datalogging can be included as an option. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 9.0 x 4.5 x 5.4 in (229 x 115 x 138 mm) |
Weight |
| <30 lbs.; 6 lbs (2.7 kg) |
Power Requirements |
| Alkaline Battery; NiMH Battery; 6 ‘D’ size alkaline or nickel cadmium batteries |
Transportability |
| Handheld |
Operating Conditions |
| 0 to 50°C (32 to 122°F) ; 0 to 95% RH, non-condensing |
Consumables |
| <$1,000/year; Sensors, calibration gases, calibration bags |
Calibration Schedule |
| Automated daily calibration |
Suggested Routine Maintenance |
| Minimal |
Available Accessories |
| Built-in sample pump Field calibrators (premixed, metered gas samples) Premixed gas cylinders Ambient air sampling pumps Sintered water guards (to protect sensors during hose downs, etc.) Duct mounting fixtures 2-oz. pure gas bottles Calibration canisters with syringe Carrying case with shoulder strap |
Data Analysis Support Equipment |
| PC |
Communications Interface |
| RS-232 |
Shelf Life |
| >5 years |
Unit Cost |
| $4,295.00 |
Maintenance Cost |
| Factory calibration $40 |
Tested For ITF-25 TIC/TIMs |
| Yes |
Other Chemical Targets |
| Detects 100 gases, but only 4 chemicals sensors may be used at a time |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm |
Start Up Time (From Cold Start To Sample Ready) |
| 1 minute |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| Continuous |
Alarm Capability |
| Yes |
Software Control |
| Yes |
Training Required |
| <1 day training |
Training Available |
| Training CD |
Manuals Available |
| Operator’s manual |
Reachback Service |
| No |
Warranties |
| 1 year |
IATA Shipping Restrictions |
| Yes; IATA regulations apply to calibration gas |