TLV Panther

TLV Panther uses a Photoionization Detector (PID) for the detection of volatile organic compounds (VOCs) such as benzene, toluene, etc. The units are microprocessor controlled, and three alarm setpoints are provided for each gas, as well as audible and visual indications if any of these alarm limits are exceeded. The kit includes a built-in sample pump, sample wand, and carrying case. Datalogging can be included as an option.

Notify me on updates of this product 

Availability: Commercially Available

Tom Chou
tom.chou@intlsensor.com
+1 800 478 4271
3 Whatney
Irvine, CA 92618-2824
www.intlsensor.com
Manufacturer
International Sensor Technology
Product Name
TLV Panther
Detection Category
Chemical
Detection Principle
Molecular Spectroscopy; Sensors;
Detection Method
Photoionization Detection; Electrochemical Detection;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
TLV Panther uses a Photoionization Detector (PID) for the detection of volatile organic compounds (VOCs) such as benzene, toluene, etc. The units are microprocessor controlled, and three alarm setpoints are provided for each gas, as well as audible and visual indications if any of these alarm limits are exceeded. The kit includes a built-in sample pump, sample wand, and carrying case. Datalogging can be included as an option.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
9.0 x 4.5 x 5.4 in (229 x 115 x 138 mm)
Weight
<30 lbs.; 6 lbs (2.7 kg)
Power Requirements
Alkaline Battery; NiMH Battery; 6 ‘D’ size alkaline or nickel cadmium batteries
Transportability
Handheld
Operating Conditions
0 to 50°C (32 to 122°F) ; 0 to 95% RH, non-condensing
Consumables
<$1,000/year; Sensors, calibration gases, calibration bags
Calibration Schedule
Automated daily calibration
Suggested Routine Maintenance
Minimal
Available Accessories
Built-in sample pump Field calibrators (premixed, metered gas samples) Premixed gas cylinders Ambient air sampling pumps Sintered water guards (to protect sensors during hose downs, etc.) Duct mounting fixtures 2-oz. pure gas bottles Calibration canisters with syringe Carrying case with shoulder strap
Data Analysis Support Equipment
PC
Communications Interface
RS-232
Shelf Life
>5 years
Unit Cost
$4,295.00
Maintenance Cost
Factory calibration $40
Tested For ITF-25 TIC/TIMs
Yes
Other Chemical Targets
Detects 100 gases, but only 4 chemicals sensors may be used at a time
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Start Up Time (From Cold Start To Sample Ready)
1 minute
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous
Alarm Capability
Yes
Software Control
Yes
Training Required
<1 day training
Training Available
Training CD
Manuals Available
Operator’s manual
Reachback Service
No
Warranties
1 year
IATA Shipping Restrictions
Yes; IATA regulations apply to calibration gas