PromethION 2

PromethION 2 (P2) devices maintain the flexibility associated with the PromethION 24 and PromethION 48 devices, but in a compact, accessible form factor. They are designed for small to medium sized academic and research labs, as well as core labs and commercial service providers, – delivering the benefits of nanopore sequencing to users with lower sample processing requirements (i.e. up to four full-length sequencing runs per week / or 200 flow cells per year). The P2 solo connects to the GridION Mk1 for operation.

Notify me on updates of this product 

Availability: In Development

+1 646 846 4446
New York Genome Center, 101 Avenue of the Americas
New York, NY 10013
East Coast USA
www.nanoporetech.com
Manufacturer
Oxford Nanopore Technologies
Product Name
PromethION 2
Detection Category
Biological
Detection Principle
Molecular;
Detection Method
Single Molecule Real-Time Sequencing;
Application
Laboratory Analysis;
Product Model Number
P2, P2 Solo
Equipment Type
Instrument
Product Synopsis
PromethION 2 (P2) devices maintain the flexibility associated with the PromethION 24 and PromethION 48 devices, but in a compact, accessible form factor. They are designed for small to medium sized academic and research labs, as well as core labs and commercial service providers, – delivering the benefits of nanopore sequencing to users with lower sample processing requirements (i.e. up to four full-length sequencing runs per week / or 200 flow cells per year). The P2 solo connects to the GridION Mk1 for operation.
Availability
In Development
Technology Readiness Level (TRL)
8
Market Entry Date
2022
User Feedback Sources
Indifferent/No user feedback
Dimensions
~4 x 8 x 4 in (10.2 x 20 x 10.2 cm)
Weight
<30 Lbs.
Power Requirements
AC/DC Line Power; < 20 watts to 1 kw
Transportability
Person-Portable
Ruggedness
None
Consumables
>$1,000/year; flow cells; sample preparation kits
Solvents/Reagents
Yes
Calibration Schedule
None
Data Analysis Support Equipment
PC, software
Communications Interface
USB
Expected Operational Life
72 hour flow cell life
Shelf Life
>5 years
Other Biological Targets
DNA, RNA, proteins
Adaptability
No; cannot detect or add new targets
Sample Introduction
Liquid
Sensitivity/Detection Limits
pg; µg
Start Up Time (From Cold Start To Sample Ready)
105 minutes
Response Time (Sample Application To Output)
>15 minutes; 1 minute to 48 hours
Total Run Time
1 minute to 48 hours
Alarm Capability
None
Software Control
On-board for P2, external for P2 solo
Other Operational Parameters
Up to 144,000 channels
Training Required
<1 week training
Manuals Available
Yes
Reachback Service
Yes
Warranties
No
Data File Type Format
.fast5
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: