5977B Mass Spec
The Agilent 5977B GC/MSD is a single quadrupole GC/MS instrument. It is ideal for applications such as environmental, chemical, petrochemical, food, forensic, pharmaceutical, and material testing. The High Efficiency Source (HES) and Inert Plus Extractor EI source maximize the number of ions that are created and transferred out of the source body and into the quadrupole analyzer.
Availability: Commercially Available
+1 816 427 5510
5301 Stevens Creek Boulevard
Santa Clara, CA 95051
USA
|
|
www.agilent.com
Manufacturer |
| Agilent Technologies |
Product Name |
| 5977B Mass Spec |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Spectrometry; |
Detection Method |
| Quadrupole Mass Spectrometry; |
Application |
| Laboratory Analysis; |
Product Model Number |
| 5977B |
Equipment Type |
| Instrument |
Product Synopsis |
| The Agilent 5977B GC/MSD is a single quadrupole GC/MS instrument. It is ideal for applications such as environmental, chemical, petrochemical, food, forensic, pharmaceutical, and material testing. The High Efficiency Source (HES) and Inert Plus Extractor EI source maximize the number of ions that are created and transferred out of the source body and into the quadrupole analyzer. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Positive User Feedback |
Dimensions |
| 34.6 x 22 x 19.7 in. (88 x 56 x 50 cm) |
Weight |
| <50 Lbs. |
Power Requirements |
| AC/DC Line Power |
Noise Produced |
| None |
Transportability |
| Benchtop/Fixed |
Ruggedness |
| Indoor Use Only |
Consumables |
| >$1,000/year |
Solvents/Reagents |
| Helium carrier gas, solvents for standards |
Calibration Schedule |
| Calibration required for each target chemical to determine GC retention time and detector response. |
Suggested Routine Maintenance |
| Source cleaning, filter cartridge replacement, pump oil change |
Data Analysis Support Equipment |
| ChemStation or Mass Hunter Software |
Communications Interface |
| USB, Ethernet, RS232 |
Expected Operational Life |
| >10 years |
Shelf Life |
| >5 years; Product lifetime indefinite with routine maintenance. Serviceability for ten years |
Tested For Chemical Agents |
| Amenable based on technology |
Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
Tested For Explosives |
| Amenable based on technology |
Tested For Narcotics |
| Amenable based on technology |
Other Chemical Targets |
| Applicable to all organic compounds amenable to GC |
Number of Library Entries |
| NIST |
Adaptability |
| Yes; user can add new targets in the field |
Sample Introduction |
| Liquid; Vapor/gas |
Sensitivity/Detection Limits |
| %; ng; µg |
False Positive Rates |
| <1% |
False Negative Rates |
| <1% |
Start Up Time (From Cold Start To Sample Ready) |
| 1 to 2 hours for internal heaters to reach operating temperatures |
Response Time (Sample Application To Output) |
| >15 minutes; 2 to 30 minutes typical response time, depending on analyte and GC method |
Software Control |
| On-board; PC |
Other Operational Parameters |
| mass range m/z 1.6 to 1050 |
Training Required |
| >1 week training |
Training Available |
| On-site and off-site training available from vendor |
Manuals Available |
| Operator’s Manual |
Warranties |
| 1 year factory warranty. 3 year extended warranty and service contract are available at additional cost. Up to 5 year service contracts are also available. |
IATA Shipping Restrictions |
| Yes; Compressed gas cylinders must be shipped ground only according to IATA regulations. |
Data File Type Format |
| XML, PDF |