Nicolet Summit
The Thermo Scientific Nicolet™ Summit FT-IR spectrometer is optimized for product assurance testing and material identification. This spectrometer implements the same FT-IR technology found on other Thermo Scientific Nicolet FT-IR models while eliminating the need for an external computer.
Availability: Commercially Available
Manufacturer |
| Thermo Fisher Scientific, Inc. |
Product Name |
| Nicolet Summit |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Mid-infrared Spectroscopy; |
Application |
| Bulk Analysis; Laboratory Analysis; |
Product Model Number |
| Summit |
Equipment Type |
| Instrument |
Product Synopsis |
| The Thermo Scientific Nicolet™ Summit FT-IR spectrometer is optimized for product assurance testing and material identification. This spectrometer implements the same FT-IR technology found on other Thermo Scientific Nicolet FT-IR models while eliminating the need for an external computer. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
Market Entry Date |
| 2019 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 13.3 x 9.6 x 12.7 in. (34 x 24 x 32 cm)
With touchscreen: 20.8 x 17 x 12.7 in. (53 x 43 x 32 cm) |
Weight |
| <30 Lbs.; 24 Lbs. (10.9 Kg)
With touchscreen 29 Lbs. (12.6 Kg) |
Power Requirements |
| AC/DC Line Power; 100-240 VAC, 47-63 Hz, 110 W |
Noise Produced |
| Negligible |
Transportability |
| Benchtop/Fixed; Small Footprint |
Ruggedness |
| None |
Consumables |
| None |
Solvents/Reagents |
| None |
Suggested Routine Maintenance |
| Minimal |
Available Accessories |
| Everest ATR |
Data Analysis Support Equipment |
| OMNIC Paradigm Software (touchscreen or desktop) |
Communications Interface |
| Wi-Fi |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Unit Cost |
| $22,000.00 |
Maintenance Cost |
| Minimal |
Tested For Chemical Agents |
| Amenable based on technology |
Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
Tested For Explosives |
| Amenable based on technology |
Tested For Narcotics |
| Amenable based on technology |
Other Chemical Targets |
| Amenable based on technology |
Number of Library Entries |
| 5,000 (std); 10,000 (PRO) |
Adaptability |
| Yes; user can add new targets in the field |
Sample Introduction |
| Liquid; Solid; |
Sensitivity/Detection Limits |
| Bulk; mg; g; % |
Start Up Time (From Cold Start To Sample Ready) |
| < 10 minutes |
Response Time (Sample Application To Output) |
| <1 minute |
Total Run Time |
| < 5 minutes |
Alarm Capability |
| None |
Software Control |
| On-board via touch screen, PC |
Other Operational Parameters |
| Signal-to-noise ratio of 40,000:1 and spectral resolution (0.45 cm-1).
Spectral Range: 8,000–350 cm-1 optimized |
Training Required |
| <1 week training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Warranties |
| 1 year parts and labor, 10 year warranty on interferometer and laser |
Data File Type Format |
| SPA, XLS |