TVA 2020 Toxic Vapor Analyzer

The Thermo Scientific™ TVA2020 Toxic Vapor Analyzer gives the user the ability to quickly detect vapors of organic and inorganic compounds. TVA2020 Toxic Vapor Analyzer can be configured as an FID analyzer (flame ionization detector) or dual detection FID analyzer and PID analyzer (photo ionization detector).

Notify me on updates of this product 

Availability: Commercially Available

+1 978 642 1132
46 Jonspin Road
Wilmington, MA 01887
USA
www.thermoscientific.com
Manufacturer
Thermo Fisher Scientific, Inc.
Product Name
TVA 2020 Toxic Vapor Analyzer
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Flame Ionization Detection (FID);Photoionization Detection;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The Thermo Scientific™ TVA2020 Toxic Vapor Analyzer gives the user the ability to quickly detect vapors of organic and inorganic compounds. TVA2020 Toxic Vapor Analyzer can be configured as an FID analyzer (flame ionization detector) or dual detection FID analyzer and PID analyzer (photo ionization detector).
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: Thermo Scientific_TVA 2020 Instruction Manual.pdf; Thermo Scientific_TVA 2020.pdf;
Dimensions
11.5 x 9 x 4 in (29.2 x 22.9 x 10.2 cm)
Weight
<30 Lbs.; 9.4 Lbs. (4.26 kg)
Power Requirements
Lithium Battery; 10 hours continuous
Transportability
Person-Portable
Ruggedness
None; intrinsically safe
Operating Conditions
15 to 95% RH
Consumables
<$1,000/year; Hydrogen gas, Calibration gas
Calibration Schedule
Yes, calibration gas used for daily calibration
Available Accessories
Sample probe, Enhanced probe, Telescoping Extension, Activated Charcoal Filter Adapter, Bluetooth Communication, and GPS.
Communications Interface
Bluetooth, GPS
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$10,000.00
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
ppm
False Positive Rates
FID Instrument – ±10% of reading or ±1.0 ppm, whichever is greater PID Instrument – ±20 % of reading or ±0.5 ppm, whichever is greater
False Negative Rates
FID Instrument – ±10% of reading or ±1.0 ppm, whichever is greater PID Instrument – ±20 % of reading or ±0.5 ppm, whichever is greater
Start Up Time (From Cold Start To Sample Ready)
15-20 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); 3.5 seconds
Alarm Capability
Audible and visual
Software Control
On-board
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
Yes