Model 2024 2% Ammonia (NH3)

The VALTRONICS Model 2024-2% NH3 is a non-dispersive infrared, gas diffusion type, gas sampling NH3 monitor for use as an OEM module. It produces a control signal proportional to NH3 concentration. The linear signal outputs of 0-5 VDC and 4-20 mA current loop may be used with any central control alarm of air monitoring system.

Notify me on updates of this product 

Availability: Commercially Available

Bill Dunlap
vti@val-tronics.com
+1 209 754 0707
3463 Double Springs Rd
Valley Springs, CA 95252
www.val-tronics.com/contact.html
Manufacturer
VTI-Valtronics, Inc.
Product Name
Model 2024 2% Ammonia (NH3)
Detection Category
Chemical
Detection Principle
Molecular Spectroscopy;
Detection Method
Non-Dispersive Infrared (NDIR);
Application
Gas Analysis;
Equipment Type
Sensor
Product Synopsis
The VALTRONICS Model 2024-2% NH3 is a non-dispersive infrared, gas diffusion type, gas sampling NH3 monitor for use as an OEM module. It produces a control signal proportional to NH3 concentration. The linear signal outputs of 0-5 VDC and 4-20 mA current loop may be used with any central control alarm of air monitoring system.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
7.75 x 4.5 x 3.75 in (197 x 115 x 96 mm)
Weight
<1 lb.; < 0.5 lbs (.23 kg)
Power Requirements
AC/DC Line Power; External power: 14.0-24.0 VDC absolute min/max
Transportability
Pocket Size
Ruggedness
Waterproof/Resistant
Operating Conditions
5 to 40°C (operating temperature) -40 to 70°C (storage temperature) 0 – 95% Relative Humidity, non-condensing
Consumables
<$1,000/year; Nitrogen and carbon dioxide calibration gases, regulator, flow meter and tubing
Calibration Schedule
Yes, zero calibration must be done every 6 months
Suggested Routine Maintenance
Rarely
Data Analysis Support Equipment
OEM optical bench, precision gas calibration kit
Shelf Life
>5 years
Unit Cost
$1,650.00
Maintenance Cost
~$200, infrequently needed
Other Chemical Targets
Ammonia and refrigerant
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm; %
Start Up Time (From Cold Start To Sample Ready)
30 to 60 seconds
Response Time (Sample Application To Output)
Continuous (<30 seconds); <10 seconds
Alarm Capability
Yes
Other Operational Parameters
$2,245 ammonia, $1,650 for refrigerant
Training Required
<1 week training
Manuals Available
User Manual
Warranties
1 yr