GM70 Hand-Held Carbon Dioxide Meter

The Vaisala CARBOCAP®, (a silicon-based infrared (IR) absorption sensor), Hand-Held Carbon Dioxide Meter GM70 is typically used for taking spot measurements in laboratories, greenhouses and mushroom farms. The meter can also be used in HVAC and industrial applications, and as a tool for checking fixed CO2 instruments. It has two optional sampling methods: diffusion or pump aspiration. Data can be logged and transferred to PC via MI70 Link software. It has a menu-based interface, a graphical LCD display and data logging capability.

Notify me on updates of this product 

Availability: Commercially Available

Fernanda Cunha
+1 781 537 1042
1862 Craig Park Court
St. Louis, MO 63146
www.vaisala.com
Manufacturer
Vaisala, Inc.
Product Name
GM70 Hand-Held Carbon Dioxide Meter
Detection Category
Chemical
Detection Principle
Molecular Spectroscopy;
Detection Method
Non-Dispersive Infrared (NDIR);
Application
Gas Analysis;
Equipment Type
Sensor
Product Synopsis
The Vaisala CARBOCAP®, (a silicon-based infrared (IR) absorption sensor), Hand-Held Carbon Dioxide Meter GM70 is typically used for taking spot measurements in laboratories, greenhouses and mushroom farms. The meter can also be used in HVAC and industrial applications, and as a tool for checking fixed CO2 instruments. It has two optional sampling methods: diffusion or pump aspiration. Data can be logged and transferred to PC via MI70 Link software. It has a menu-based interface, a graphical LCD display and data logging capability.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
2.2 x .73 in (55 x 18.5 mm)
Weight
<5 lbs.; GM70 Pump with GMP221/222 probe 24.7 oz (700 g)
Power Requirements
NiMH Battery; AC/DC Line Power; Rechargeable NiMH battery pack with AC-adapter
Transportability
Pocket Size
Operating Conditions
-20 to 60°C, 0 to 100% RH, non-condensing, 700 to 1300 hPa Pressure, 0-10 m/s flow
Consumables
>$1,000/year; Nafion membrane tubing, calibration software kit, zero calibration gas N2, high end reference gas (mixture of CO2 and N2), GM70 pump, o-rings
Calibration Schedule
Yes, performed using a calibration kit (every 2 yrs)
Suggested Routine Maintenance
Minimal
Available Accessories
Connection cable for fixed CO2 instruments, MI70 Link software with USB cable or serial port cable, calibration adapter, carrying case, spare probe
Communications Interface
USB
Unit Cost
$210.00
Maintenance Cost
Minimal
Other Chemical Targets
Carbon Dioxide
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Start Up Time (From Cold Start To Sample Ready)
30 seconds, 15 minute full specifications
Response Time (Sample Application To Output)
<1 minute; 63% < 20 seconds (GMP221) 63% < 30 seconds (GMP222)
Alarm Capability
Audible alarm and LCD with backlight, graphic trend
Software Control
Yes, by using the M170 Link program
Training Required
<1 day training
Manuals Available
Yes
Warranties
1 year, limited