GM70 Hand-Held Carbon Dioxide Meter
The Vaisala CARBOCAP®, (a silicon-based infrared (IR) absorption sensor), Hand-Held Carbon Dioxide Meter GM70 is typically used for taking spot measurements in laboratories, greenhouses and mushroom farms. The meter can also be used in HVAC and industrial applications, and as a tool for checking fixed CO2 instruments. It has two optional sampling methods: diffusion or pump aspiration. Data can be logged and transferred to PC via MI70 Link software. It has a menu-based interface, a graphical LCD display and data logging capability.
Availability: Commercially Available
Fernanda Cunha
+1 781 537 1042
1862 Craig Park Court
St. Louis, MO 63146
|
|
www.vaisala.com
Manufacturer |
| Vaisala, Inc. |
Product Name |
| GM70 Hand-Held Carbon Dioxide Meter |
Detection Category |
| Chemical |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Non-Dispersive Infrared (NDIR); |
Application |
| Gas Analysis; |
Equipment Type |
| Sensor |
Product Synopsis |
| The Vaisala CARBOCAP®, (a silicon-based infrared (IR) absorption sensor), Hand-Held Carbon Dioxide Meter GM70 is typically used for taking spot measurements in laboratories, greenhouses and mushroom farms. The meter can also be used in HVAC and industrial applications, and as a tool for checking fixed CO2 instruments. It has two optional sampling methods: diffusion or pump aspiration. Data can be logged and transferred to PC via MI70 Link software. It has a menu-based interface, a graphical LCD display and data logging capability. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 2.2 x .73 in (55 x 18.5 mm) |
Weight |
| <5 lbs.; GM70 Pump with GMP221/222 probe 24.7 oz (700 g) |
Power Requirements |
| NiMH Battery; AC/DC Line Power; Rechargeable NiMH battery pack with AC-adapter |
Transportability |
| Pocket Size |
Operating Conditions |
| -20 to 60°C, 0 to 100% RH, non-condensing, 700 to 1300 hPa Pressure, 0-10 m/s flow |
Consumables |
| >$1,000/year; Nafion membrane tubing, calibration software kit, zero calibration gas N2, high end reference gas (mixture of CO2 and N2), GM70 pump, o-rings |
Calibration Schedule |
| Yes, performed using a calibration kit (every 2 yrs) |
Suggested Routine Maintenance |
| Minimal |
Available Accessories |
| Connection cable for fixed CO2 instruments, MI70 Link software with USB cable or serial port cable, calibration adapter, carrying case, spare probe |
Communications Interface |
| USB |
Unit Cost |
| $210.00 |
Maintenance Cost |
| Minimal |
Other Chemical Targets |
| Carbon Dioxide |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm |
Start Up Time (From Cold Start To Sample Ready) |
| 30 seconds, 15 minute full specifications |
Response Time (Sample Application To Output) |
| <1 minute; 63% < 20 seconds (GMP221) 63% < 30 seconds (GMP222) |
Alarm Capability |
| Audible alarm and LCD with backlight, graphic trend |
Software Control |
| Yes, by using the M170 Link program |
Training Required |
| <1 day training |
Manuals Available |
| Yes |
Warranties |
| 1 year, limited |