Ultramat 6

Can measure up to 4 gas components at once, with a maximum of 3 infrared sensitive gases. Two mount styles are available: rack mount and tabletop. Ultramat 6 has a permanent reference gas.

Notify me on updates of this product 

Availability: Commercially Available

Stuart Hunter
Technical
+1 713 939 3202
One Internet Plaza
Johnson City, TN 37604-1663
USA
Manufacturer
Siemens Johnson City (SIAC)
Product Name
Ultramat 6
Detection Category
Chemical
Detection Principle
Molecular Spectroscopy;
Detection Method
Non-Dispersive Infrared (NDIR); Infrared (IR) Spectroscopy ;
Application
Gas Analysis;
Equipment Type
Sensor
Product Synopsis
Can measure up to 4 gas components at once, with a maximum of 3 infrared sensitive gases. Two mount styles are available: rack mount and tabletop. Ultramat 6 has a permanent reference gas.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
19 x 14.25 x 6.5 in (483 x 362 x 165 mm)
Weight
>50 lbs.; ~10 kg, Field mount weighs 50-55 lbs, Rack mount weighs 30-35 lbs
Power Requirements
AC/DC Line Power; 110 V, standard AC power
Transportability
Benchtop/Fixed
Ruggedness
None; Not designed for rough handling or moist weather
Operating Conditions
5 to 45°C (operating temperature) -20 to 70°C (storage and transport temperature) < 90% relative humidity (storage and transport) 700 – 1200 hPa
Consumables
<$1,000/year; Calibration gas, nitrogen (for a reference gas), sample pump
Calibration Schedule
Yes, “0” calibrations required
Suggested Routine Maintenance
Diaphragms may tear
Data Analysis Support Equipment
Filter and compressor/cooler
Communications Interface
RS 485, PROFIBUS, SIPROM GA
Unit Cost
$11,000.00
Maintenance Cost
Minimal
Other Chemical Targets
O2, CO, CO2, CH4, SO2, NO, C2H4, C6H14, N2O
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
Avoid toxic, flammable, or corrosive environments. Avoid excess pressure
Start Up Time (From Cold Start To Sample Ready)
Warm up period ~30 minutes, with heated version ~90 minutes, maximum accuracy after 2 hours
Response Time (Sample Application To Output)
<1 minute; T90 dependent on dead time and selectable damping, < 30 seconds with a sample gas flow of ~1.2 L/min (oxygen channel) T90 dependent on length of the sample gas cell, the sample line, and the programmable damping
Alarm Capability
Yes, alarms are programmable
Software Control
Yes
Other Operational Parameters
Pressure changes may affect instrument operation
Training Required
<1 week training
Training Available
Yes, 1 day training available
Manuals Available
Yes
Warranties
18 month