Ultramat 6
Can measure up to 4 gas components at once, with a maximum of 3 infrared sensitive gases. Two mount styles are available: rack mount and tabletop. Ultramat 6 has a permanent reference gas.
Availability: Commercially Available
Stuart Hunter
Technical
+1 713 939 3202
One Internet Plaza
Johnson City, TN 37604-1663
USA
|
|
Manufacturer |
| Siemens Johnson City (SIAC) |
Product Name |
| Ultramat 6 |
Detection Category |
| Chemical |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Non-Dispersive Infrared (NDIR); Infrared (IR) Spectroscopy ; |
Application |
| Gas Analysis; |
Equipment Type |
| Sensor |
Product Synopsis |
| Can measure up to 4 gas components at once, with a maximum of 3 infrared sensitive gases. Two mount styles are available: rack mount and tabletop. Ultramat 6 has a permanent reference gas. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 19 x 14.25 x 6.5 in (483 x 362 x 165 mm) |
Weight |
| >50 lbs.; ~10 kg, Field mount weighs 50-55 lbs, Rack mount weighs 30-35 lbs |
Power Requirements |
| AC/DC Line Power; 110 V, standard AC power |
Transportability |
| Benchtop/Fixed |
Ruggedness |
| None; Not designed for rough handling or moist weather |
Operating Conditions |
| 5 to 45°C (operating temperature) -20 to 70°C (storage and transport temperature) < 90% relative humidity (storage and transport) 700 – 1200 hPa |
Consumables |
| <$1,000/year; Calibration gas, nitrogen (for a reference gas), sample pump |
Calibration Schedule |
| Yes, “0” calibrations required |
Suggested Routine Maintenance |
| Diaphragms may tear |
Data Analysis Support Equipment |
| Filter and compressor/cooler |
Communications Interface |
| RS 485, PROFIBUS, SIPROM GA |
Unit Cost |
| $11,000.00 |
Maintenance Cost |
| Minimal |
Other Chemical Targets |
| O2, CO, CO2, CH4, SO2, NO, C2H4, C6H14, N2O |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm |
Known Interferents/Inhibitors |
| Avoid toxic, flammable, or corrosive environments. Avoid excess pressure |
Start Up Time (From Cold Start To Sample Ready) |
| Warm up period ~30 minutes, with heated version ~90 minutes, maximum accuracy after 2 hours |
Response Time (Sample Application To Output) |
| <1 minute; T90 dependent on dead time and selectable damping, < 30 seconds with a sample gas flow of ~1.2 L/min (oxygen channel) T90 dependent on length of the sample gas cell, the sample line, and the programmable damping |
Alarm Capability |
| Yes, alarms are programmable |
Software Control |
| Yes |
Other Operational Parameters |
| Pressure changes may affect instrument operation |
Training Required |
| <1 week training |
Training Available |
| Yes, 1 day training available |
Manuals Available |
| Yes |
Warranties |
| 18 month |