SAFEAIR®
The SafeAir® system consists of a direct reading colorimetric badge and a color comparison chart. SafeAir® badges are available for 21 different gases. Provides immediate visual indication when specific chemical is present. Homogeneous and stable color formation due to coated indicator layer.
Availability: Commercially Available
+1 800 808 2234
2557 Production Road
Virginia Beach, VA 23454
USA
|
|
www.morphtec.com
Manufacturer |
| Morphix Technologies |
Product Name |
| SAFEAIR® |
Detection Category |
| Chemical |
Detection Principle |
| Colorimetric; |
Detection Method |
| Colorimetric; |
Application |
| Emergency Response; Gas Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The SafeAir® system consists of a direct reading colorimetric badge and a color comparison chart. SafeAir® badges are available for 21 different gases. Provides immediate visual indication when specific chemical is present. Homogeneous and stable color formation due to coated indicator layer. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 2.9 x 1.6 x 0.04 in (7.3 x 4 x 0.1 cm) |
Weight |
| <5 lbs.; 3.3 lb (1.5 g) |
Power Requirements |
| None |
Transportability |
| Pocket Size |
Operating Conditions |
| Operates in most environments |
Available Accessories |
| Strap clip needed to hold badge to clothing |
Shelf Life |
| <1 year; Badges may be refrigerated in sealed pouch for up to 1 year |
Unit Cost |
| $165 for box of 50 |
Tested For ITF-25 TIC/TIMs |
| Ammonia, aniline, carbon dioxide, carbon monoxide, chlorine, chlorine dioxide, dimethyl amine, formaldehyde, hydrazine, hydrides, hydrogen chloride, hydrogen sulfide, MDI, mercury, nitrogen dioxide, ozone, phosgene, sulfur dioxide, TDI, and UDMH |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm; ppb |
Known Interferents/Inhibitors |
| Cross interferences are listed in the operating instructions for each analyte badge. Example: for the chlorine badge, bromine and iodine are known cross-interferences, and hydrogen chloride and hydrochloric acid at concentrations greater than 1 ppm can seriously impair the performance of the badge. |
Start Up Time (From Cold Start To Sample Ready) |
| 30 seconds |
Response Time (Sample Application To Output) |
| <5 minutes; 2 minutes |
Total Run Time |
| Continuous |
Alarm Capability |
| Visual Alarm (color change) |
Training Required |
| <1 hour training |
Training Available |
| No |
Manuals Available |
| Operating instructions included in each box |
Reachback Service |
| No |
Warranties |
| Guaranteed accurate throughout the shelf life period. Labeled with expiration date. |
Approved Vendors |
| Amazon.com |