VIR 9550
The VIR-9000 Series is a compact, lightweight benchtop FTIR system. The standard instrument includes a hermetically sealed interferometer, DLATGS detector, high intensity source, and automatic alignment. Options can be added for increased sensitivity, optional spectral ranges including NIR, and battery operation. Accessories include the Smart-Tech, gas cells, microscopes, fiber optics, and open path analyzers.
Availability: DISCONTINUED
(410) 822-1220
8649 Commerce Drive
Easton, MD 21601 USA
|
|
Manufacturer |
| Jasco, Inc. |
Product Name |
| VIR 9550 |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Mid-infrared Spectroscopy; |
Application |
| Laboratory Analysis; Screening; Bulk Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The VIR-9000 Series is a compact, lightweight benchtop FTIR system. The standard instrument includes a hermetically sealed interferometer, DLATGS detector, high intensity source, and automatic alignment. Options can be added for increased sensitivity, optional spectral ranges including NIR, and battery operation. Accessories include the Smart-Tech, gas cells, microscopes, fiber optics, and open path analyzers. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 12.6 x 10.4 x 13.6 in (320 × 265 × 346 mm) |
Weight |
| <50 lbs.; 39.8 lbs (18.7 kg) |
Power Requirements |
| AC/DC Line Power; Requires AC power; power supply unit included |
Transportability |
| Benchtop/Fixed |
Ruggedness |
| None; Not militarized, drop sensitive |
Consumables |
| None |
Available Accessories |
| Fiber-coupled measurement system Gas measurement system |
Data Analysis Support Equipment |
| PC |
Unit Cost |
| $42,500.00 |
Adaptability |
| Yes; users can add new targets in the field and create custom searchable spectral libraries. Most organic chemicals are capable of producing a searchable Infrared spectrum. |
Sample Introduction |
| Vapor/Gas; Solid; Liquid |
Sensitivity/Detection Limits |
| Bulk; mg; g |
Known Interferents/Inhibitors |
| Successful identification of an unknown is dependent on the presence of the corresponding reference spectrum in the library. Analysis of mixtures can produce erroneous search results. |
Response Time (Sample Application To Output) |
| <1 minute; 10,000:1 S/N ratio or more for 1 minute acquisition |
Software Control |
| Yes |
Other Operational Parameters |
| 0.5 to 16 cm–1 resolution, Spectral range: 400 to 7000 cm–1 |
Training Required |
| <1 week training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Warranties |
| 1 year |
IATA Shipping Restrictions |
| No |