HazCat Rocket Fuel Identification

The HazCat® Rocket Fuel Test Kit is a two-part test for identifying components of rocket fuel. One test identifies aluminum metal and/or ammonium perchlorate. A second test identifies aged, oxidized aluminum if the first test is negative. The test is performed in water, reducing the chance of accidental ignition.

Notify me on updates of this product 

Availability: Commercially available

Stacia Law
+1 800 543 5487
P.O. Box 929 3919 Bootjack Lane
Mariposa, CA 95338
www.hazcat.com
Manufacturer
Haztech Systems, Inc.
Product Name
HazCat Rocket Fuel Identification
Detection Category
Chemical
Detection Principle
Colorimetric;
Detection Method
Colorimetric;
Application
Emergency Response;
Product Model Number
KT1036
Equipment Type
Instrument
Product Synopsis
The HazCat® Rocket Fuel Test Kit is a two-part test for identifying components of rocket fuel. One test identifies aluminum metal and/or ammonium perchlorate. A second test identifies aged, oxidized aluminum if the first test is negative. The test is performed in water, reducing the chance of accidental ignition.
Availability
Commercially available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
16 × 20 × 8 in (407 x 508 x 204 mm)
Weight
<30 lbs.; 10 lbs (4.5 kg)
Power Requirements
None
Transportability
Handheld
Ruggedness
Waterproof/Resistant; Watertight protective pelican case
Operating Conditions
Sensitive to extreme temperatures
Consumables
<$1,000/year; dependent on use. Disposable test tubes, pipettes, scoops, test strips, and reagents
Solvents/Reagents
Water solubility test; perchlorate test; sodium hydroxide; metal extraction test; aluminum test
Suggested Routine Maintenance
Expiration dates of reagents should be periodically checked. Replace reagents as required.
Available Accessories
Hardware, cases, additional solvents
Expected Operational Life
Reagent shelf life
Shelf Life
<1 year
Unit Cost
$490.00
Maintenance Cost
< $300 per year
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Other Chemical Targets
Aluminum metal, ammonium perchlorate, rocket fuel
Sample Introduction
Solid
Sensitivity/Detection Limits
ppm
Start Up Time (From Cold Start To Sample Ready)
< 1 minute
Response Time (Sample Application To Output)
>15 minutes; 20 minutes
Total Run Time
Seconds
Training Required
<1 day training
Training Available
Available at manufacturer’s site or at customer facility
Manuals Available
User manual and MSDS manual, flow charts, and field sheet packets
Warranties
1 year
IATA Shipping Restrictions
Title 29 CFR 1910.120 Req. for ID, IATA shipping confirmation. Exempt-level quantities of reagents