M908

DISCONTINUED; contact manufacturer for more information or see MX908 for newer offering. The M908™ is a hand held mass spectrometer that can operate in continuous vapor sampling mode or have solid and liquid samples introduced via the thermal desorption port. It is designed to be fully deconnable and operates for > 4 hrs on a single battery charge. Weighing 2.0 kg (4.4 lbs), the M908 is designed for operation in full protective gear.

Notify me on updates of this product 

Availability: DISCONTINUED

John Kenneweg
Vice President of Sales, Safety & Security
john.kenneweg@908devices.com
+1 857 254 1500
27 Drydock Avenue
Boston, MA 02210
USA
Jim Kane
Director of Federal Program
jim.kane@908devices.com
+1 757 746 5554
www.908devices.com
Manufacturer
908 Devices, Inc.
Product Name
M908
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry;
Detection Method
Ion Trap Mass Spectrometry;High-Pressure Mass Spectrometry;
Application
Emergency Response; Gas Analysis; Screening; Trace Analysis; Bulk Analysis; Forensics;
Product Model Number
M908
Equipment Type
Instrument
Product Synopsis
DISCONTINUED; contact manufacturer for more information or see MX908 for newer offering. The M908™ is a hand held mass spectrometer that can operate in continuous vapor sampling mode or have solid and liquid samples introduced via the thermal desorption port. It is designed to be fully deconnable and operates for > 4 hrs on a single battery charge. Weighing 2.0 kg (4.4 lbs), the M908 is designed for operation in full protective gear.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
Market Entry Date
Fall 2014
User Feedback Sources
MRIGlobal hands-on experience; positive user feedback
Dimensions
8.7 x 7.3 x 3 in (22 x 18.5 x 7.6 cm)
Weight
<5 lbs.; 4.4 Lbs. (2.0 kg)
Power Requirements
Lithium Battery; AC/DC Line Power; Rechargeable Battery (> 4 hours) or standard AC power
Noise Produced
Negligible
Transportability
Handheld
Ruggedness
Waterproof/Resistant; Dust; Vibration/Shock; MIL-STD-810G, Shock and vibration testing.
Operating Conditions
0 to 43°C (32 to 110°F)
Consumables
<$1,000/year; Thermal desorption swabs, $95 per 100 TD swabs, about $300 per year, depending on frequency of use
Suggested Routine Maintenance
Minimal - designed for non-technical users
Data Analysis Support Equipment
None
Communications Interface
USB
Expected Operational Life
Indefinite
Shelf Life
>5 years; (Li-ion battery pack has a lifetime of 3 years)
Unit Cost
$50,000.00
Tested For Chemical Agents
GA, GB, GD, GF, HD, L, VX
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
Yes
Other Chemical Targets
Yes
Number of Library Entries
~ 90
Adaptability
Yes; manufacturer can add new targets to detector
Sample Introduction
Vapor/Gas; Liquid; Solid
Sensitivity/Detection Limits
ppb; ppm
Known Interferents/Inhibitors
None
Start Up Time (From Cold Start To Sample Ready)
< 2 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Variable
Alarm Capability
Audible and Visual
Software Control
On-board
Other Operational Parameters
User collects sample with swabs, Mass Range: 55 to 400 Da; configurable to higher mass
Training Required
<1 day training
Training Available
Yes, 4 hour on-site
Manuals Available
Yes
Reachback Service
Yes
Warranties
1 year
ITAR/EAR Export Regulations
No
IATA Shipping Restrictions
Yes; Li-ion battery
Data File Type Format
PDF, JPG, CSV