PM1604 Series
Dosimeters provide real-time environmental radiation monitoring. The devices can be used independently or as a part of operational dosimetry system for everyday and emergency radiation control, and can be tailored to the specific needs of customers. Dosimeters have two independent alarm thresholds within all dose equivalent rate (DER) and dose equivalent (DE) measurement ranges. Audible and visual alarms alert users when the preset thresholds have been exceeded. All data accumulated and stored in non-volatile memory can be transmitted via infrared channel to a PC for further processing and analysis.
The instruments' hermetic, shockproof and water-resistant case and the fluorescent backlight on LCD screen allow for easy operation and precision even in the most harsh and unfavorable environments. The
dosimeters are highly sensitive and can register even the slightest changes in the natural background radiation.
Availability: Commercially Available
| Manufacturer |
| Polimaster, Inc. |
| Product Name |
| PM1604 Series |
| Detection Category |
| Radiological/Nuclear; |
| Detection Principle |
| Geiger-Muller Detectors; |
| Detection Method |
| Geiger-Muller Detectors; |
| Application |
| Dosimeters; |
| Product Model Number |
| PM1604A, PM1604B |
| Equipment Type |
| Instrument; |
| Product Synopsis |
| Dosimeters provide real-time environmental radiation monitoring. The devices can be used independently or as a part of operational dosimetry system for everyday and emergency radiation control, and can be tailored to the specific needs of customers. Dosimeters have two independent alarm thresholds within all dose equivalent rate (DER) and dose equivalent (DE) measurement ranges. Audible and visual alarms alert users when the preset thresholds have been exceeded. All data accumulated and stored in non-volatile memory can be transmitted via infrared channel to a PC for further processing and analysis.
The instruments' hermetic, shockproof and water-resistant case and the fluorescent backlight on LCD screen allow for easy operation and precision even in the most harsh and unfavorable environments. The
dosimeters are highly sensitive and can register even the slightest changes in the natural background radiation. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Supporting Documentation |
| Docs: _PM1604_pm1604AB_en.pdf; |
| Dimensions |
| 1.97 x 3.54 x 0.75 in (5.0 x 9.0 x 1.9 cm) |
| Weight |
| <1 lb.; 0.19 lb (0.085 kg) |
| Power Requirements |
| Lithium Battery; CR 2032 battery (9 months) |
| Transportability |
| Handheld; |
| Ruggedness |
| Hermetic, shockproof and water-resistant case; IP67 |
| Operating Conditions |
| -20°? to +70°? (-4 to 158°F); up to 98% at 35°C |
| Consumables |
| Battery |
| Solvents/Reagents |
| None |
| Suggested Routine Maintenance |
| None |
| Available Accessories |
| Clip |
| Communications Interface |
| IrDA |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Maintenance Cost |
| None |
| Radiological Targets |
| Gamma, X-ray |
| Adaptability |
| No |
| Sample Introduction |
| Radioactive Particle |
| Sensitivity/Detection Limits |
| µSv/h |
| Start Up Time (From Cold Start To Sample Ready) |
| Seconds to minutes |
| Total Run Time |
| Continuous (< 30 seconds) |
| Alarm Capability |
| Audible, visual |
| Software Control |
| On-board |
| Training Required |
| < 1 hour |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Reachback Service |
| Yes |
| Warranties |
| Yes |