SVG-2 Simulator
The SVG-2 SIM is a highly realistic, cost-effective training solution for the Thermo Fischer Scientific SVG2 detector.
Availability: Commercially Available
| Manufacturer |
| Argon Electronics |
| Product Name |
| SVG-2 Simulator |
| Detection Category |
| Radiological/Nuclear; |
| Detection Principle |
| Simulation Training; |
| Detection Method |
| Electromagnetic / Magnetic Point Contact Source; |
| Application |
| Simulation Training; |
| Product Model Number |
| F367N01-L004 (Base Module) F367N02-L004 (Alpha,Beta,Gamma Probes only) |
| Equipment Type |
| Accessory; |
| Product Synopsis |
| The SVG-2 SIM is a highly realistic, cost-effective training solution for the Thermo Fischer Scientific SVG2 detector. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| Market Entry Date |
| N/A |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 3" x 6.3" x 3.5" |
| Weight |
| <8 Lbs. |
| Power Requirements |
| Same commercial or rechargable batteries as real detector. |
| Noise Produced |
| Same as Manufacturer |
| Transportability |
| Handheld; |
| Ruggedness |
| Same as Manufacturer |
| Operating Conditions |
| Same as Manufacturer |
| Consumables |
| Commercial Batteries Only |
| Calibration Schedule |
| N/A |
| Suggested Routine Maintenance |
| Requires no preventative maintenance and spares are minimized to reduce the cost of ownership. |
| Available Accessories |
| Instructor remote control |
| Data Analysis Support Equipment |
| N/A |
| Communications Interface |
| N/A |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Maintenance Cost |
| None |
| Sample Introduction |
| Simulated Radiation Activity Detection |
| Start Up Time (From Cold Start To Sample Ready) |
| <2 minutes |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds); < 10 seconds |
| Total Run Time |
| Continuous |
| Alarm Capability |
| Visual/Audible |
| Software Control |
| Onboard |
| Other Operational Parameters |
| Inverse square law (1/r2) response within real detector tolerance.
Simulation of external Alpha, Beta, Gamma probe.
Simulation of user body shielding for source location.
Realistic representation of different shielding effects.
Selectable units of measurement (Sv/hr, Rem, CPS).
Same human interface as real SVG-2.
Configurable menu settings.
Dose and dose rate alarm settings.
Same commercial batteries or remote / vehicle power as real detector.
No regular calibration.
No preventative maintenance.
PlumeSIM compatible. |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Reachback Service |
| N/A |
| Warranties |
| 1 YR - Return to Manufactuer |
| ITAR/EAR Export Regulations |
| NO |
| U.S. EAR Compliant |
| Yes |
| IATA Shipping Restrictions |
| NO |
| Approved Vendors |
| Contact Argon Electronics |
| Data File Type Format |
| N/A |