RadSim GS4 Gamma Simulator
Detection Category
Radiological/Nuclear;
Detection Principle
Simulation Training;
Detection Method
Electromagnetic;
Application
Simulation Training;
Product Model Number
F407X02-NUS4
Equipment Type
Accessory;
Product Synopsis
The Radsim Gamma series is so realistic your students will believe the source is live, yet is entirely safe, environmentally friendly and cost effective.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
N/A
User Feedback Sources
Indifferent/No user feedback
Dimensions
5" x 6" x 3"
Weight
<1 Lbs
Power Requirements
Recharable OnBoard Battery
Noise Produced
Same as Manufacturer
Transportability
Handheld;
Ruggedness
Same as Manufacturer
Operating Conditions
Same as Manufacturer
Consumables
N/A
Calibration Schedule
N/A
Suggested Routine Maintenance
Requires no preventative maintenance and spares are minimized to reduce the cost of ownership.
Available Accessories
N/A
Data Analysis Support Equipment
N/A
Communications Interface
N/A
Expected Operational Life
Indefinite
Shelf Life
>5 years
Maintenance Cost
None
Sample Introduction
Simulated Radiation Source
Start Up Time (From Cold Start To Sample Ready)
<2 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); < 10 seconds
Total Run Time
Continuous
Alarm Capability
Visual/Audible
Software Control
Onboard
Other Operational Parameters
Safe simulation Gamma / Neutron sorce to provide Dose rate and Dose readings that trigger personal safety actions and the provision of recommendations leading to effective decision making. Inverse square law (1/r2) response. Shielding effects of different materials. Consistent readingsobtained across instruments each time the student revisits the same location within the exercise.
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Reachback Service
N/A
Warranties
1 YR - Return to Manufactuer
ITAR/EAR Export Regulations
NO
U.S. EAR Compliant
Yes
IATA Shipping Restrictions
NO
Approved Vendors