DolMo I Simulator
Gamma survey radiation training simulator enables high reading dose and dose rate exercises to be executed safely without ionizing radiation sources.
Availability: Commercially Available
Manufacturer |
| Argon Electronics |
Product Name |
| DolMo I Simulator |
Detection Category |
| Radiological/Nuclear; |
Detection Principle |
| Simulation Training; |
Detection Method |
| Electromagnetic / Magnetic Point Contact Source; |
Application |
| Simulation Training; |
Product Model Number |
| Contact Argon Electronics |
Equipment Type |
| Accessory; |
Product Synopsis |
| Gamma survey radiation training simulator enables high reading dose and dose rate exercises to be executed safely without ionizing radiation sources. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
Market Entry Date |
| N/A |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 5.5" x 2.75" x 1.25" |
Weight |
| <1 Lbs |
Power Requirements |
| Same commercial or rechargable batteries as real detector. |
Noise Produced |
| Same as Manufacturer |
Transportability |
| Handheld; |
Ruggedness |
| Same as Manufacturer |
Operating Conditions |
| Same as Manufacturer |
Consumables |
| Commercial Batteries Only |
Calibration Schedule |
| N/A |
Suggested Routine Maintenance |
| Requires no preventative maintenance and spares are minimized to reduce the cost of ownership. |
Available Accessories |
| N/A |
Data Analysis Support Equipment |
| N/A |
Communications Interface |
| N/A |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Maintenance Cost |
| None |
Sample Introduction |
| N/A |
Start Up Time (From Cold Start To Sample Ready) |
| <2 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds); < 10 seconds |
Total Run Time |
| Continuous |
Alarm Capability |
| Visual/Audible |
Software Control |
| Onboard |
Other Operational Parameters |
| Dose rate and Dose readings that trigger personal safety actions and the provision of recommendations leading to effective decision making.
Alarms indicating potentially hazardous radiation levels.
Inverse square law (1/r2) response.
Shielding effects of different materials.
The importance of using shielding for personal dose reduction.
Consistent readings across instruments each time the student revisits the same location within the exercise. PlumeSIM compatible. |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Reachback Service |
| N/A |
Warranties |
| 1 YR - Return to Manufactuer |
ITAR/EAR Export Regulations |
| NO |
U.S. EAR Compliant |
| Yes |
IATA Shipping Restrictions |
| NO |
Approved Vendors |
| Contact Argon Electronics |
Data File Type Format |
| N/A |