SSAMI
The Safe Sampling and Multiplexing Indicator (SSAMI) device is coupled with a Lateral Flow Strip Test Assembly Container. The SSAMI – Sampler is common to all contaminated surface sampling and can be used to sample biological agents, chemical agents, explosives, narcotics, and other pathogens. It comprises a pre-moistened sponge that is used to collect the sample. Once returned to the housing, the sample is safely contained and allows ‘no contamination’ transfer of at least 1.8 mls sample to be injected into the SSAMI – Detector. The SSAMI – Detector, containing up to 12 threat detectors, will then analyze and display the results. A second sample is retained in the SSAMI – Sampler which can be used for confirmatory testing in a second SSAMI – Detector, retained for further laboratory analysis or safely stored as evidence. The SSAMI can be configured to customer specifications.
Availability: Commercially Available
| Manufacturer |
| SE Defense Technologies, LLC |
| Product Name |
| SSAMI |
| Detection Category |
| Biological |
| Detection Principle |
| Immunological; |
| Detection Method |
| Lateral Flow Hand Held Immunoassay; |
| Application |
| Emergency Response; Detection; Screening; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The Safe Sampling and Multiplexing Indicator (SSAMI) device is coupled with a Lateral Flow Strip Test Assembly Container. The SSAMI – Sampler is common to all contaminated surface sampling and can be used to sample biological agents, chemical agents, explosives, narcotics, and other pathogens. It comprises a pre-moistened sponge that is used to collect the sample. Once returned to the housing, the sample is safely contained and allows ‘no contamination’ transfer of at least 1.8 mls sample to be injected into the SSAMI – Detector. The SSAMI – Detector, containing up to 12 threat detectors, will then analyze and display the results. A second sample is retained in the SSAMI – Sampler which can be used for confirmatory testing in a second SSAMI – Detector, retained for further laboratory analysis or safely stored as evidence. The SSAMI can be configured to customer specifications. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| Market Entry Date |
| 2020 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 5.5 x 1.6 x 1.6 in (14 x 4 x 4 cm) |
| Weight |
| <1 lb.; 3 oz (85g) |
| Power Requirements |
| None |
| Noise Produced |
| None |
| Transportability |
| Pocket Size |
| Operating Conditions |
| Store 4 to 28°C (39 to 82°F) |
| Consumables |
| <$1,000/year; Test strips, buffer vials |
| Solvents/Reagents |
| Buffer |
| Calibration Schedule |
| None |
| Suggested Routine Maintenance |
| None |
| Available Accessories |
| Interpretation cards |
| Shelf Life |
| <5 years; 24 Months |
| Unit Cost |
| $127.00 |
| Maintenance Cost |
| None |
| Tested For Biological Agents |
| B. anthracis (Anthrax), Y. pestis (Plague) Ricin, Botulinum Toxia A/B, F. tularensis (Tularemia), Brucella spp., Burkholderia mallei, Staphylococcal Enterotoxin B. (SEB) |
| Other Biological Targets |
| Ames spores, Vegetative cells, Brucella abortus, Brucella melitensis |
| Adaptability |
| No; cannot detect or add new targets |
| Sample Introduction |
| Solid; Liquid |
| Sensitivity/Detection Limits |
| ng; B.anthracis, Ames spores: 5x107 org/mL, B.anthracis, Vegetative cells: 5 x 106 org/mL, F.tularensis: 1x107 org/mL, Y.pestis: 1x108 org/mL, Y.pestis:1x108 org/mL, B.mallei:1x106 org/mL, Brucella abortus: 5x107 org/mL, Brucella melitensis: 5x107 org/mL, SEB: 20ng/mL, Ricin: 10ng/mL, Botulinum Neurotoxin Type A: 20ng/mL, Botulinum Neurotoxin Type B: 20ng/mL |
| Known Interferents/Inhibitors |
| B.cereus, Y.psedutuberculosis, Y.similis, chalk dust |
| Start Up Time (From Cold Start To Sample Ready) |
| Immediate |
| Response Time (Sample Application To Output) |
| <15 minutes |
| Total Run Time |
| 15 minutes |
| Alarm Capability |
| Visual |
| Training Required |
| <1 hour training |
| Training Available |
| Yes and online video |
| Manuals Available |
| Yes |
| Reachback Service |
| No |
| Warranties |
| None |
| ITAR/EAR Export Regulations |
| Yes; UK export controlled, licenses required |
| IATA Shipping Restrictions |
| No |
| Approved Vendors |
| Normeca Asia (http://www.normeca-asia.jp/) , EPE (http://epequip.com/contact/) , Romtech (http://romtech.ro/en/) |