StellarRAM
The StellarRAM units are handheld Raman detectors available in either 785 nm (SR model) or 1064 nm (IG model). They are Android software based, contain a replaceable lithium ion battery, and a point/shoot accessory.
Availability: Commercially Available
| Manufacturer |
| StellarNet |
| Product Name |
| StellarRAM |
| Detection Category |
| Chemical; Explosives |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Raman Spectroscopy; |
| Application |
| Bulk Analysis;Emergency Response;Screening; |
| Product Model Number |
| Raman-SR, Raman-IG |
| Equipment Type |
| Instrument; |
| Product Synopsis |
| The StellarRAM units are handheld Raman detectors available in either 785 nm (SR model) or 1064 nm (IG model). They are Android software based, contain a replaceable lithium ion battery, and a point/shoot accessory. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 4 x 7 x 1.5 in. (10.2 x 17.8 x 3.8 cm) |
| Weight |
| <5 Lbs. |
| Power Requirements |
| Lithium Battery; USB |
| Noise Produced |
| None |
| Transportability |
| Handheld |
| Consumables |
| <$1,000/year; sample vials |
| Suggested Routine Maintenance |
| Routine cleaning |
| Available Accessories |
| Point/shoot accessory, vial holder |
| Data Analysis Support Equipment |
| Android OS |
| Communications Interface |
| USB |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Unit Cost |
| $20,000 (SR), $40,000 (IG) |
| Maintenance Cost |
| Minimal |
| Tested For Chemical Agents |
| Amenable based on technology |
| Tested For ITF-25 TIC/TIMs |
| Yes |
| Tested For Explosives |
| Yes |
| Tested For Narcotics |
| Yes |
| Number of Library Entries |
| DEMO libraries include Plastic, Drugs/Narcotics, Veterinary Drugs, Pesticides, Household Chemicals, Food Additives, Explosives, Chemicals, Hazardous Chemicals, Carcinogens, & Corrosives. |
| Adaptability |
| Yes; user can add new targets in the field |
| Sample Introduction |
| Liquid;Solid; |
| Sensitivity/Detection Limits |
| %; g |
| Response Time (Sample Application To Output) |
| <5 minutes |
| Software Control |
| On-board, PC |
| Other Operational Parameters |
| Resolution: 12 cm-1 (SR), 11 cm-1 (IG)
Range: 200-2000 cm-1 (SR), 200-2250 cm-1 (IG) |
| Training Required |
| <1 day training |
| Manuals Available |
| Yes |
| IATA Shipping Restrictions |
| Yes; Lithium ion battery restrictions |
| Data File Type Format |
| PDF |