xZone Series
The Dräger xZone 5000 transforms the Dräger personal gas detection instruments X-am 5000 into area monitoring devices. This enables the connection of multiple monitors to form a line or enclose a given area with detectors. The unit communicates wirelessly with additional units if desired.
Availability: Commercially Available
+1 800 437 2437
7256 South Sam Houston Parkway, Suite 100
Houston, TX 77085
USA
|
+49 451 8843
Moislinger Allee 53-78
23581 Lübeck
Germany
|
www.draeger.com
Manufacturer |
| Dräger Safety, Inc. |
Product Name |
| xZone Series |
Detection Category |
| Chemical; |
Detection Principle |
| Sensors; |
Detection Method |
| Electrochemical Detection; |
Application |
| Emergency Response; Gas Analysis; |
Product Model Number |
| 5000, 5500 |
Equipment Type |
| Instrument |
Product Synopsis |
| The Dräger xZone 5000 transforms the Dräger personal gas detection instruments X-am 5000 into area monitoring devices. This enables the connection of multiple monitors to form a line or enclose a given area with detectors. The unit communicates wirelessly with additional units if desired. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 20 x 12 x 12 in (49 x 30 x 30 cm) |
Weight |
| <30 Lbs.; 15 Lbs. (7 kg) |
Power Requirements |
| Lithium Battery; 12 Ah battery (> 60 hours) 24 Ah battery (>120 hours) |
Transportability |
| Person-Portable |
Ruggedness |
| Waterproof/Resistant; Dust; Extreme Temperatures/Humidity; IP67 |
Operating Conditions |
| –20 to 50°C (–4 to 122°F); 10 to 95% RH |
Consumables |
| <$1,000/year; Sensing elements Optional calibration kits |
Calibration Schedule |
| Every 6 months |
Available Accessories |
| Charging Accessories Pump Accessories Communication accessories Cases Calibration Accessories |
Data Analysis Support Equipment |
| Drager CC-Vision PC software |
Communications Interface |
| USB, wireless |
Shelf Life |
| <5 years; 2 years |
Unit Cost |
| $3,845.00 |
Maintenance Cost |
| Recommended annual maintenance by manufacturer |
Tested For ITF-25 TIC/TIMs |
| Yes |
Other Chemical Targets |
| Combustible gases |
Sample Introduction |
| Vapor/Gas |
Known Interferents/Inhibitors |
| Hydrocarbons can decrease sensitivity |
Start Up Time (From Cold Start To Sample Ready) |
| < 15 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Software Control |
| On-board, PC |
Training Required |
| <1 day training |
Training Available |
| Yes, operator training CD |
Manuals Available |
| Yes |
Warranties |
| 3 years |
ITAR/EAR Export Regulations |
| Yes; Calibration gas cylinders are likely ground transport only |
IATA Shipping Restrictions |
| Yes; Calibration gas cylinders are likely ground transport only |