xZone Series

The Dräger xZone 5000 transforms the Dräger personal gas detection instruments X-am 5000 into area monitoring devices. This enables the connection of multiple monitors to form a line or enclose a given area with detectors. The unit communicates wirelessly with additional units if desired.

Notify me on updates of this product 

Availability: Commercially Available

+1 800 437 2437
7256 South Sam Houston Parkway, Suite 100
Houston, TX 77085
USA
+49 451 8843
Moislinger Allee 53-78
23581 Lübeck
Germany
www.draeger.com
Manufacturer
Dräger Safety, Inc.
Product Name
xZone Series
Detection Category
Chemical;
Detection Principle
Sensors;
Detection Method
Electrochemical Detection;
Application
Emergency Response; Gas Analysis;
Product Model Number
5000, 5500
Equipment Type
Instrument
Product Synopsis
The Dräger xZone 5000 transforms the Dräger personal gas detection instruments X-am 5000 into area monitoring devices. This enables the connection of multiple monitors to form a line or enclose a given area with detectors. The unit communicates wirelessly with additional units if desired.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
20 x 12 x 12 in (49 x 30 x 30 cm)
Weight
<30 Lbs.; 15 Lbs. (7 kg)
Power Requirements
Lithium Battery; 12 Ah battery (> 60 hours) 24 Ah battery (>120 hours)
Transportability
Person-Portable
Ruggedness
Waterproof/Resistant; Dust; Extreme Temperatures/Humidity; IP67
Operating Conditions
–20 to 50°C (–4 to 122°F); 10 to 95% RH
Consumables
<$1,000/year; Sensing elements Optional calibration kits
Calibration Schedule
Every 6 months
Available Accessories
Charging Accessories Pump Accessories Communication accessories Cases Calibration Accessories
Data Analysis Support Equipment
Drager CC-Vision PC software
Communications Interface
USB, wireless
Shelf Life
<5 years; 2 years
Unit Cost
$3,845.00
Maintenance Cost
Recommended annual maintenance by manufacturer
Tested For ITF-25 TIC/TIMs
Yes
Other Chemical Targets
Combustible gases
Sample Introduction
Vapor/Gas
Known Interferents/Inhibitors
Hydrocarbons can decrease sensitivity
Start Up Time (From Cold Start To Sample Ready)
< 15 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Software Control
On-board, PC
Training Required
<1 day training
Training Available
Yes, operator training CD
Manuals Available
Yes
Warranties
3 years
ITAR/EAR Export Regulations
Yes; Calibration gas cylinders are likely ground transport only
IATA Shipping Restrictions
Yes; Calibration gas cylinders are likely ground transport only