NexION Series ICP-MS
The NexION ICP-MS systems are laboratory benchtop systems. The 1000 model is better for high-throughput, routine, multi-element, trace-level analyses. The 2000 model is versatile to accommodate any sample matrix, interference, and particle size. The 5000 model is a high resolution with four quadrupoles and includes an Extended Dynamic Range (EDR) that increases linear dynamic range to 10^12, allowing to run both high and low concentration analytes in a single analytical run.
Availability: Commercially available
| Manufacturer |
| Perkin Elmer |
| Product Name |
| NexION Series ICP-MS |
| Detection Category |
| Chemical |
| Detection Principle |
| Elemental Analysis; |
| Detection Method |
| Inductively Coupled Plasma Mass Spectrometry; |
| Application |
| Laboratory Analysis; |
| Product Model Number |
| NexION 5000, NexION 2000, NexION 1000 |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The NexION ICP-MS systems are laboratory benchtop systems. The 1000 model is better for high-throughput, routine, multi-element, trace-level analyses. The 2000 model is versatile to accommodate any sample matrix, interference, and particle size. The 5000 model is a high resolution with four quadrupoles and includes an Extended Dynamic Range (EDR) that increases linear dynamic range to 10^12, allowing to run both high and low concentration analytes in a single analytical run. |
| Availability |
| Commercially available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Weight |
| >50 Lbs. |
| Power Requirements |
| AC/DC Line Power |
| Noise Produced |
| Negligible |
| Transportability |
| Benchtop/Fixed |
| Ruggedness |
| Indoor use only |
| Operating Conditions |
| Indoor use only |
| Consumables |
| >$1,000/year |
| Solvents/Reagents |
| Mobile phase, solvent for standards |
| Suggested Routine Maintenance |
| RF coil requires no maintenance or cooling |
| Data Analysis Support Equipment |
| Syngistix™ for ICP-MS software (v. 3.0 or higher) |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Tested For Chemical Agents |
| Amenable by Technology |
| Tested For ITF-25 TIC/TIMs |
| Amenable by Technology |
| Tested For Explosives |
| Amenable by Technology |
| Tested For Narcotics |
| Amenable by Technology |
| Other Chemical Targets |
| Amenable by Technology |
| Adaptability |
| No; cannot detect or add new targets |
| Sample Introduction |
| Liquid |
| Sensitivity/Detection Limits |
| µg; % |
| Response Time (Sample Application To Output) |
| <15 minutes |
| Alarm Capability |
| None |
| Software Control |
| PC |
| Other Operational Parameters |
| Acquisition speed 100,000 points/sec |
| Training Required |
| >1 week training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Reachback Service |
| Yes |
| Warranties |
| 1 year |