RF-6000

The RF-6000 is a fluorescence spectrometer with extended wavelength range. Multiple spectral techniques are available for use with this instrument, such as bioluminescence, chemiluminescence, and electro-luminescence. Fluorescence quantum yield and efficiency can be measured with an integrating sphere. Scanning speed of 60,000 nm/min.

Notify me on updates of this product 

Availability: Commercially Available

Greg Feldman
Sr. Field Sales Engineer
gsfeldman@shimadzu.com
1-913-888-9449, Ext. 1270
8052 Reeder Street
Lenexa, KS 66214
Midwest Regional Office
Jason Kuchar, Ph. D.
Life Science account Manager
jakuchar@shimadzu.com
1-913-888-9449, Ext. 1265
8052 Reeder Street
Lenexa, KS 66214
Midwest Regional Office
www.ssi.shimadzu.com
Manufacturer
Shimadzu
Product Name
RF-6000
Detection Category
Chemical; Biological; Explosives;
Detection Principle
Molecular Spectroscopy;
Detection Method
Florescence;
Application
Laboratory Analysis;
Equipment Type
Instrument
Product Synopsis
The RF-6000 is a fluorescence spectrometer with extended wavelength range. Multiple spectral techniques are available for use with this instrument, such as bioluminescence, chemiluminescence, and electro-luminescence. Fluorescence quantum yield and efficiency can be measured with an integrating sphere. Scanning speed of 60,000 nm/min.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Weight
>50 Lbs.
Power Requirements
AC/DC Line Power
Noise Produced
None
Transportability
Benchtop/Fixed
Ruggedness
Indoor Use Only
Operating Conditions
Indoor Use Only
Consumables
<$1,000/year
Solvents/Reagents
None
Data Analysis Support Equipment
Software, PC
Expected Operational Life
Indefinite
Shelf Life
>5 years
Tested For Chemical Agents
Amenable based on Technology
Tested For ITF-25 TIC/TIMs
Amenable based on Technology
Tested For Explosives
Amenable based on Technology
Tested For Narcotics
Amenable based on Technology
Other Chemical Targets
Amenable based on Technology
Tested For Biological Agents
No
Other Biological Targets
No
Radiological Targets
No
Sample Introduction
Liquid
Sensitivity/Detection Limits
ng
Response Time (Sample Application To Output)
<5 minutes
Alarm Capability
None
Software Control
PC
Other Operational Parameters
Indefinite; 2,000 hour long-life Xe lamp
Training Required
<1 week training
Training Available
Yes
Manuals Available
Yes
Warranties
Yes
Please enter contact info.
Email Address: 
Company: 
Name: 