MIRA DS/XTR DS
The Mira DS is a handheld Raman device designed for illicit substances and explosives identification. A stand-off attachment and a contact ball probe attachment are available and is compatible with SERS substrates.
The MIRA XTR DS uses a fluorescence-free 785 nm laser, sampling up to a 2 m distance. Multiple attachment options for SERS, vial, right angle, contact probe to suit different operational needs.
Availability: Commercially Available
| Manufacturer |
| Metrohm |
| Product Name |
| MIRA DS/XTR DS |
| Detection Category |
| Chemical; Explosives |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Raman Spectroscopy; |
| Application |
| Bulk Analysis;Emergency Response;Screening; |
| Product Model Number |
| MIRA DS, MIRA XTR DS |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The Mira DS is a handheld Raman device designed for illicit substances and explosives identification. A stand-off attachment and a contact ball probe attachment are available and is compatible with SERS substrates.
The MIRA XTR DS uses a fluorescence-free 785 nm laser, sampling up to a 2 m distance. Multiple attachment options for SERS, vial, right angle, contact probe to suit different operational needs. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| Market Entry Date |
| 2021 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Supporting Documentation |
| Docs: Metrohm MIRA XTR DS.pdf; |
| Weight |
| <5 Lbs. |
| Power Requirements |
| Lithium battery |
| Transportability |
| Handheld |
| Ruggedness |
| Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; Vibration/Shock; Military Spec 810G, IP67. |
| Consumables |
| <$1,000/year; sample vials |
| Calibration Schedule |
| Yes |
| Available Accessories |
| Contact ball probe, SERS attachment, right angle attachment, vial attachment. XTR model: Autofocus standoff attachment. |
| Data Analysis Support Equipment |
| HAZMASTERG3 Software App |
| Communications Interface |
| USB, Bluetooth to an Android device |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Unit Cost |
| $35,000.00 |
| Tested For Chemical Agents |
| Amenable based on technology |
| Tested For ITF-25 TIC/TIMs |
| Yes |
| Tested For Explosives |
| Yes |
| Tested For Narcotics |
| Yes |
| Number of Library Entries |
| >20,000 |
| Adaptability |
| Yes; user can add new targets in the field and create custom searchable libraries |
| Sample Introduction |
| Liquid;Solid; |
| Sensitivity/Detection Limits |
| %; g; mg |
| Known Interferents/Inhibitors |
| Flourescence |
| Response Time (Sample Application To Output) |
| <5 minutes |
| Total Run Time |
| 5 to 20 minutes |
| Alarm Capability |
| Visual |
| Software Control |
| On-board, PC |
| Other Operational Parameters |
| The XTR DS uses an extraction process (not subtraction) to mitigate fluorescence. Laser 785 nm. Sampling distance up to 2 m. Scan delay option. |
| Training Required |
| <1 day training |
| Training Available |
| Vendor on-site |
| Manuals Available |
| Yes |
| Warranties |
| Yes |
| ITAR/EAR Export Regulations |
| None |
| IATA Shipping Restrictions |
| Yes; Lithium ion battery |
| Approved Vendors |
| Rapiscan Systems |