HAPSITE CDT Chemical Identification System
The HAPSITE® CDT is a person-portable Gas Chromatograph/Quadrupole Mass Spectrometer (GC/MS) . Hazardous response teams use this to identify and quantify narcotics, chemical agents and toxic chemicals on-site to make life, health and public safety decisions. Detects, identifies and quantifies low levels of narcotics, chemical weapons, toxic chemicals and explosives. Delivers results in minutes with reproducible data to complete risk assessments and support informed, on-the-spot decision-making. The handheld, lightweight cartridge-based sampling system enhances portability, and allows the analytical module to stay out of hot zones and allows users to collect data while on the move. The split/splitless injector port allows material sampling with syringe injection.
Availability: In Development
Manufacturer |
| INFICON |
Product Name |
| HAPSITE CDT Chemical Identification System |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Spectrometry;Chromatography; |
Detection Method |
| Quadrupole Mass Spectrometry;Gas Chromatography; |
Application |
| Emergency Response;Screening;Gas Analysis;Trace Analysis; |
Product Model Number |
| CDT |
Equipment Type |
| Instrument |
Product Synopsis |
| The HAPSITE® CDT is a person-portable Gas Chromatograph/Quadrupole Mass Spectrometer (GC/MS) . Hazardous response teams use this to identify and quantify narcotics, chemical agents and toxic chemicals on-site to make life, health and public safety decisions. Detects, identifies and quantifies low levels of narcotics, chemical weapons, toxic chemicals and explosives. Delivers results in minutes with reproducible data to complete risk assessments and support informed, on-the-spot decision-making. The handheld, lightweight cartridge-based sampling system enhances portability, and allows the analytical module to stay out of hot zones and allows users to collect data while on the move. The split/splitless injector port allows material sampling with syringe injection. |
Availability |
| In Development |
Technology Readiness Level (TRL) |
| 8 |
Market Entry Date |
| 2022 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 51.3 x 50.4 x 20.0 cm |
Weight |
| <50 Lbs. |
Power Requirements |
| AC/DC Line Power; 15V Li-Ion battery |
Noise Produced |
| Negligible |
Transportability |
| Person-Portable |
Ruggedness |
| Waterproof/Resistant; Dust; CE; IP65, sealed to withstand decon |
Consumables |
| >$1,000/year; GC column, getter pump, ionizer. Requires carrier and internal standard gases in custom canisters. |
Solvents/Reagents |
| Gases |
Calibration Schedule |
| Yes, with internal, removable gas canister |
Suggested Routine Maintenance |
| Neg pump and ion pump |
Data Analysis Support Equipment |
| Laptop |
Communications Interface |
| Ethernet interface to PC or laptop. On-board GPS; records time and location of sample data files. GPS can be easily disconnected. USB Port. 802.11G wireless. |
Expected Operational Life |
| 10+ years |
Shelf Life |
| >5 years |
Unit Cost |
| >$50,000 per unit |
Tested For Chemical Agents |
| All G agents, VX, VLX, RVX, HD, A-series |
Tested For ITF-25 TIC/TIMs |
| Yes |
Tested For Narcotics |
| Fentanyl, carfentanil, pharmaceutical based agents |
Other Chemical Targets |
| Yes |
Number of Library Entries |
| NIST Library Loaded, AMDIS |
Adaptability |
| Yes; user can add new targets in the field |
Sample Introduction |
| Vapor/Gas;Liquid; |
Sensitivity/Detection Limits |
| ppb; ppm; ng |
Known Interferents/Inhibitors |
| no known Interferences |
False Positive Rates |
| <1% False Positive and Negative Rate |
Start Up Time (From Cold Start To Sample Ready) |
| 12 minutes |
Response Time (Sample Application To Output) |
| <1 minute; >15 minutes; Real-time in MS Only mode, 5 to 25 minutes in GC/MS mode |
Total Run Time |
| 5 to 15 Minutes |
Alarm Capability |
| Visual, audible |
Software Control |
| Stand-alone and PC control. On-board hard drive. |
Training Required |
| <1 week training |
Training Available |
| Yes. Recommend 1-week training; available on-site or at factory. |
Manuals Available |
| Yes |
Reachback Service |
| Yes |
IATA Shipping Restrictions |
| Yes; Compressed gas cylinders must be shipped ground only according to IATA restrictions. |