HAPSITE CDT Chemical Identification System

The HAPSITE® CDT is a person-portable Gas Chromatograph/Quadrupole Mass Spectrometer (GC/MS) . Hazardous response teams use this to identify and quantify narcotics, chemical agents and toxic chemicals on-site to make life, health and public safety decisions. Detects, identifies and quantifies low levels of narcotics, chemical weapons, toxic chemicals and explosives. Delivers results in minutes with reproducible data to complete risk assessments and support informed, on-the-spot decision-making. The handheld, lightweight cartridge-based sampling system enhances portability, and allows the analytical module to stay out of hot zones and allows users to collect data while on the move. The split/splitless injector port allows material sampling with syringe injection.

Notify me on updates of this product 

Availability: In Development

Rebecca Robertson
DOD/DHS Account Manager
rebecca.robertson@inficon.com
+1 315 434 2580
Two Technology Place
East Syracuse, NY 13057
www.inficon.com
Manufacturer
INFICON
Product Name
HAPSITE CDT Chemical Identification System
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry;Chromatography;
Detection Method
Quadrupole Mass Spectrometry;Gas Chromatography;
Application
Emergency Response;Screening;Gas Analysis;Trace Analysis;
Product Model Number
CDT
Equipment Type
Instrument
Product Synopsis
The HAPSITE® CDT is a person-portable Gas Chromatograph/Quadrupole Mass Spectrometer (GC/MS) . Hazardous response teams use this to identify and quantify narcotics, chemical agents and toxic chemicals on-site to make life, health and public safety decisions. Detects, identifies and quantifies low levels of narcotics, chemical weapons, toxic chemicals and explosives. Delivers results in minutes with reproducible data to complete risk assessments and support informed, on-the-spot decision-making. The handheld, lightweight cartridge-based sampling system enhances portability, and allows the analytical module to stay out of hot zones and allows users to collect data while on the move. The split/splitless injector port allows material sampling with syringe injection.
Availability
In Development
Technology Readiness Level (TRL)
8
Market Entry Date
2022
User Feedback Sources
Indifferent/No user feedback
Dimensions
51.3 x 50.4 x 20.0 cm
Weight
<50 Lbs.
Power Requirements
AC/DC Line Power; 15V Li-Ion battery
Noise Produced
Negligible
Transportability
Person-Portable
Ruggedness
Waterproof/Resistant; Dust; CE; IP65, sealed to withstand decon
Consumables
>$1,000/year; GC column, getter pump, ionizer. Requires carrier and internal standard gases in custom canisters.
Solvents/Reagents
Gases
Calibration Schedule
Yes, with internal, removable gas canister
Suggested Routine Maintenance
Neg pump and ion pump
Data Analysis Support Equipment
Laptop
Communications Interface
Ethernet interface to PC or laptop. On-board GPS; records time and location of sample data files. GPS can be easily disconnected. USB Port. 802.11G wireless.
Expected Operational Life
10+ years
Shelf Life
>5 years
Unit Cost
>$50,000 per unit
Tested For Chemical Agents
All G agents, VX, VLX, RVX, HD, A-series
Tested For ITF-25 TIC/TIMs
Yes
Tested For Narcotics
Fentanyl, carfentanil, pharmaceutical based agents
Other Chemical Targets
Yes
Number of Library Entries
NIST Library Loaded, AMDIS
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Vapor/Gas;Liquid;
Sensitivity/Detection Limits
ppb; ppm; ng
Known Interferents/Inhibitors
no known Interferences
False Positive Rates
<1% False Positive and Negative Rate
Start Up Time (From Cold Start To Sample Ready)
12 minutes
Response Time (Sample Application To Output)
<1 minute; >15 minutes; Real-time in MS Only mode, 5 to 25 minutes in GC/MS mode
Total Run Time
5 to 15 Minutes
Alarm Capability
Visual, audible
Software Control
Stand-alone and PC control. On-board hard drive.
Training Required
<1 week training
Training Available
Yes. Recommend 1-week training; available on-site or at factory.
Manuals Available
Yes
Reachback Service
Yes
IATA Shipping Restrictions
Yes; Compressed gas cylinders must be shipped ground only according to IATA restrictions.
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: