Micro GC System

Agilent 990 Micro GC systems are designed for gas analysis. They provide quick startup and response time even if changing measurement locations frequently. Various configuration options offer up to four channels of separation and detection. The GC can be used in the lab, on-line, or in the field. They use only 10% of the power and carrier gas compared to a conventional lab GC.

Notify me on updates of this product 

Availability: Commercially Available

+1 816 427 5510
5301 Stevens Creek Boulevard
Santa Clara, CA 95051
USA
www.agilent.com
Manufacturer
Agilent Technologies
Product Name
Micro GC System
Detection Category
Chemical; Explosives
Detection Principle
Chromatography; Spectrometry;
Detection Method
Gas Chromatography;
Application
Laboratory Analysis; Trace Analysis;
Product Model Number
990, 490
Equipment Type
Instrument
Product Synopsis
Agilent 990 Micro GC systems are designed for gas analysis. They provide quick startup and response time even if changing measurement locations frequently. Various configuration options offer up to four channels of separation and detection. The GC can be used in the lab, on-line, or in the field. They use only 10% of the power and carrier gas compared to a conventional lab GC.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
11.1 x 5.7 x 13 in. (28.3 x 14.5 x 32.9 cm)
Weight
<30 Lbs.; 16 Lbs. (7.3 kg)
Power Requirements
AC/DC Line Power
Noise Produced
None
Transportability
Benchtop/Fixed
Ruggedness
Indoor Use Only
Operating Conditions
0 to 50°C (32 to 122°F), 5 to 90% RH
Consumables
>$1,000/year; Typical for GC (helium carrier gas, GC columns, ferrules, injection port liners, chemical standards, etc.)
Solvents/Reagents
Helium, hydrogen, nitrogen and argon carrier gas options
Calibration Schedule
Calibration required for each target chemical to determine GC retention time and detector response.
Suggested Routine Maintenance
Typical for GC
Available Accessories
Optional thermal desorption unit, detectors
Data Analysis Support Equipment
ChemStation or OpenLab Software
Communications Interface
USB, Ethernet, RS232
Expected Operational Life
>10 years
Shelf Life
>5 years; Product lifetime indefinite with routine maintenance. Serviceability for ten years
Tested For Chemical Agents
Amenable based on technology
Tested For ITF-25 TIC/TIMs
Amenable based on technology
Tested For Explosives
Amenable based on technology
Tested For Narcotics
Amenable based on technology
Other Chemical Targets
Amenable based on technology
Number of Library Entries
NIST
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Vapor/gas
Sensitivity/Detection Limits
ppm
False Positive Rates
<1%
False Negative Rates
<1%
Start Up Time (From Cold Start To Sample Ready)
<30 minutes
Response Time (Sample Application To Output)
<15 minutes
Software Control
On-board; PC
Training Required
>1 week training
Training Available
On-site and off-site training available from vendor
Manuals Available
Operator’s Manual
Warranties
1 year factory warranty. 3 year extended warranty and service contract are available at additional cost. Up to 5 year service contracts are also available.
IATA Shipping Restrictions
Yes; Compressed gas cylinders must be shipped ground only according to IATA regulations.
Data File Type Format
XML, PDF