7800 Series GC

The 7890B Gas Chromatograph (GC) System is a widely used GC system, featuring temperature controls, precise injection systems, and high performance Electronic Pneumatic Control (EPC) modules for retention time and area count repeatability. Capillary Flow Technology (CFT) provides unique instrument capabilities, such as multi-dimension gas chromatography (GC-GC/Deans Switch), comprehensive two-dimension gas chromatography (GCxGC) with flow modulation, and backflush at the beginning, middle, or end of the analytical column.

Notify me on updates of this product 

Availability: Commercially Available

+1 816 427 5510
5301 Stevens Creek Boulevard
Santa Clara, CA 95051
USA
www.agilent.com
Manufacturer
Agilent Technologies
Product Name
7800 Series GC
Detection Category
Chemical; Explosives
Detection Principle
Chromatography; Spectrometry;
Detection Method
Gas Chromatography; Quadrupole Mass Spectrometry; Flame Photometric Detection (FPD); Flame Ionization Detection (FID);
Application
Laboratory Analysis; Trace Analysis;
Product Model Number
7890B, 7820A
Equipment Type
Instrument
Product Synopsis
The 7890B Gas Chromatograph (GC) System is a widely used GC system, featuring temperature controls, precise injection systems, and high performance Electronic Pneumatic Control (EPC) modules for retention time and area count repeatability. Capillary Flow Technology (CFT) provides unique instrument capabilities, such as multi-dimension gas chromatography (GC-GC/Deans Switch), comprehensive two-dimension gas chromatography (GCxGC) with flow modulation, and backflush at the beginning, middle, or end of the analytical column.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Positive User Feedback
Weight
>50 Lbs.
Power Requirements
AC/DC Line Power
Noise Produced
None
Transportability
Benchtop/Fixed
Ruggedness
Indoor Use Only
Operating Conditions
15 to 35°C (-4 to 95°F), 5 to 90% RH
Consumables
>$1,000/year; Typical for GC (helium carrier gas, GC columns, ferrules, injection port liners, chemical standards, etc.)
Solvents/Reagents
Helium carrier gas, solvents for standards
Calibration Schedule
Calibration required for each target chemical to determine GC retention time and detector response.
Suggested Routine Maintenance
Typical for GC
Available Accessories
Optional thermal desorption unit, detectors
Data Analysis Support Equipment
ChemStation or Mass Hunter Software
Communications Interface
USB, Ethernet, RS232
Expected Operational Life
>10 years
Shelf Life
>5 years; Product lifetime indefinite with routine maintenance. Serviceability for ten years
Unit Cost
$30,000.00
Tested For Chemical Agents
Amenable based on technology
Tested For ITF-25 TIC/TIMs
Amenable based on technology
Tested For Explosives
Amenable based on technology
Tested For Narcotics
Amenable based on technology
Other Chemical Targets
Applicable to all organic compounds amenable to GC
Number of Library Entries
NIST
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Liquid; Vapor/gas
Sensitivity/Detection Limits
%; ng; µg
False Positive Rates
<1%
False Negative Rates
<1%
Start Up Time (From Cold Start To Sample Ready)
1 to 2 hours for internal heaters to reach operating temperatures
Response Time (Sample Application To Output)
>15 minutes; 2 to 30 minutes typical response time, depending on analyte and GC method
Software Control
On-board; PC
Training Required
>1 week training
Training Available
On-site and off-site training available from vendor
Manuals Available
Operator’s Manual
Warranties
1 year factory warranty. 3 year extended warranty and service contract are available at additional cost. Up to 5 year service contracts are also available.
IATA Shipping Restrictions
Yes; Compressed gas cylinders must be shipped ground only according to IATA regulations.
Data File Type Format
XML, PDF