6500 Series LC/Q-TOF

The 6545 is a mid-range Q-TOF for untargeted sample analysis. The 6546 contains the highest resolution. The 6560 delivers collision cross sections and structural information. The 6550 iFunnel is the most sensitive in the series!

Notify me on updates of this product 

Availability: Commercially Available

+1 816 427 5510
5301 Stevens Creek Boulevard
Santa Clara, CA 95051
USA
www.agilent.com
Manufacturer
Agilent Technologies
Product Name
6500 Series LC/Q-TOF
Detection Category
Chemical; Biological; Explosives;
Detection Principle
Spectrometry; Chromatography;
Detection Method
Liquid Chromatography; Quadrupole Mass Spectrometry;
Application
Laboratory Analysis;
Product Model Number
6545, 6545XT, 6546, 6560, 6530, 6550
Equipment Type
Instrument
Product Synopsis
The 6545 is a mid-range Q-TOF for untargeted sample analysis. The 6546 contains the highest resolution. The 6560 delivers collision cross sections and structural information. The 6550 iFunnel is the most sensitive in the series!
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Weight
>50 Lbs.
Power Requirements
AC/DC Line Power
Noise Produced
None
Transportability
Benchtop/Fixed
Ruggedness
Indoor Use Only
Consumables
>$1,000/year
Solvents/Reagents
Mobile Phase components and solvents for standards
Calibration Schedule
Calibration required for each target chemical to determine LC retention time and detector response.
Data Analysis Support Equipment
MassHunter Software
Communications Interface
USB, Ethernet, RS232
Expected Operational Life
>10 years
Shelf Life
>5 years; Product lifetime indefinite with routine maintenance. Serviceability for ten years
Tested For Chemical Agents
Amenable based on technology
Tested For ITF-25 TIC/TIMs
Amenable based on technology
Tested For Explosives
Amenable based on technology
Tested For Narcotics
Amenable based on technology
Other Chemical Targets
Yes
Tested For Biological Agents
Yes
Other Biological Targets
Yes
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Liquid
Sensitivity/Detection Limits
%; ng; µg
False Positive Rates
<1%
False Negative Rates
<1%
Start Up Time (From Cold Start To Sample Ready)
1 to 2 hours
Response Time (Sample Application To Output)
<15 minutes
Software Control
On-board; PC
Training Required
>1 week training
Training Available
On-site and off-site training available from vendor
Manuals Available
Operator’s Manual
Warranties
1 year factory warranty. 3 year extended warranty and service contract are available at additional cost. Up to 5 year service contracts are also available.
Data File Type Format
XML, PDF