1200 Series Infinity II LC Systems
The Infinity II series LC systems are benchtop HPLC and UPLC configurable systems for laboratory analyses. The 1260 and 1290 models include more integration options, better efficiency and higher capacity features than the base model 1220.
Availability: Commercially Available
+1 816 427 5510
5301 Stevens Creek Boulevard
Santa Clara, CA 95051
USA
|
|
www.agilent.com
Manufacturer |
| Agilent Technologies |
Product Name |
| 1200 Series Infinity II LC Systems |
Detection Category |
| Chemical; Biological; Explosives; |
Detection Principle |
| Chromatography; Spectrometry; |
Detection Method |
| Liquid Chromatography; |
Application |
| Laboratory Analysis; Trace Analysis; |
Product Model Number |
| 1220, 1260, 1290 |
Equipment Type |
| Instrument |
Product Synopsis |
| The Infinity II series LC systems are benchtop HPLC and UPLC configurable systems for laboratory analyses. The 1260 and 1290 models include more integration options, better efficiency and higher capacity features than the base model 1220. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Weight |
| >50 Lbs. |
Power Requirements |
| AC/DC Line Power |
Noise Produced |
| None |
Transportability |
| Benchtop/Fixed |
Ruggedness |
| Indoor Use Only |
Consumables |
| >$1,000/year; columns, mobile phase, tubing |
Solvents/Reagents |
| Yes; mobile phase |
Calibration Schedule |
| Calibration required for each target chemical to determine LC retention time and detector response. |
Available Accessories |
| Detectors |
Data Analysis Support Equipment |
| Software |
Expected Operational Life |
| >10 years |
Shelf Life |
| >5 years |
Tested For Chemical Agents |
| Amenable based on technology |
Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
Tested For Explosives |
| Amenable based on technology |
Tested For Narcotics |
| Amenable based on technology |
Other Chemical Targets |
| Amenable based on technology |
Adaptability |
| Yes; user can add new targets in the field |
Sample Introduction |
| Liquid |
Sensitivity/Detection Limits |
| ng; µg |
False Positive Rates |
| <1% |
False Negative Rates |
| <1% |
Start Up Time (From Cold Start To Sample Ready) |
| 1 to 2 hours to prime and equilibrate |
Response Time (Sample Application To Output) |
| <15 minutes |
Software Control |
| PC |
Other Operational Parameters |
| 0.05 to 5 mL/min flow range |
Training Required |
| >1 week training |
Training Available |
| On-site and off-site training available from vendor |
Manuals Available |
| Operator’s Manual |
Warranties |
| 1 year factory warranty. 3 year extended warranty and service contract are available at additional cost. Up to 5 year service contracts are also available. |