X-555
The X-555 is a handheld XRF and LIBS instrument containing a 55 kV X-ray tube for detection on elements like Ag, Cd, Sn, Sb and Ba, making it suited for RCRA applications and EPA Method 6200. Up to three automated beam settings provide performance across the periodic table from Mg to U.
Availability: Commercially Available
Don Sackett
sales@sciaps.com
+1 339 927 9455
2 Constitution Way
Woburn, MA 01801
|
SciAps Manufacturing & Service
+1 339 927 9455
5452 Aerospace Drive
Laramie, WY 82070
|
www.sciaps.com
Manufacturer |
| SciAps, Inc. |
Product Name |
| X-555 |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Elemental Analysis; |
Detection Method |
| X-ray Fluorescence;Laser Induced Breakdown Spectroscopy; |
Application |
| Bulk Analysis;Screening; |
Product Model Number |
| X-555 |
Equipment Type |
| Instrument |
Product Synopsis |
| The X-555 is a handheld XRF and LIBS instrument containing a 55 kV X-ray tube for detection on elements like Ag, Cd, Sn, Sb and Ba, making it suited for RCRA applications and EPA Method 6200. Up to three automated beam settings provide performance across the periodic table from Mg to U. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
Market Entry Date |
| 2021 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 7.25 x 10.5 x 4.5 in. (18.4 x 26.7 x 11.4 cm) |
Weight |
| <5 Lbs.; 2.98 lbs. (1.35 kg) with battery |
Power Requirements |
| AC/DC Line Power; Lithium Battery; Hot swappable |
Transportability |
| Handheld |
Ruggedness |
| Extreme Temperatures/Humidity |
Operating Conditions |
| -12 to 54°C (10 to 130°F) |
Consumables |
| <$1,000/year; sample cups |
Calibration Schedule |
| Internal 316 stainless check standard for calibration verification and wavelength scale validation |
Available Accessories |
| Test stand, Kickstand |
Data Analysis Support Equipment |
| ProfileBuilder PC Software |
Communications Interface |
| Wi-Fi, Bluetooth, USB, GPS |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Other Chemical Targets |
| Elements Mg to U |
Number of Library Entries |
| 32 elements |
Adaptability |
| Yes; manufacturer can add new targets to detector |
Sample Introduction |
| Solid;Liquid; |
Sensitivity/Detection Limits |
| Bulk; % |
Known Interferents/Inhibitors |
| Fluorescence |
Start Up Time (From Cold Start To Sample Ready) |
| <5 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| <5 minutes |
Alarm Capability |
| None |
Software Control |
| On-board; PC |
Other Operational Parameters |
| Excitation source: 5 W X-ray Tube. Max 55 kV, 200 uA. Au anode. |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Warranties |
| Yes |
IATA Shipping Restrictions |
| Yes; Lithium-ion battery |