Coriolis Micro
The Coriolis Micro is a microbial air sampler used for bio- contamination control assessment. Through its liquid cyclonic technology, it can collect viral particles in a chosen collection liquid. Coriolis µ samples are compatible with all rapid microbiology techniques such as qPCR or microarrays, and also NGS analysis. Virus concentrations as low as 100 genomes copies/m3 can be detected in collected air samples.
Availability: Commercially Available
+1 844 7 BERTIN
2096 Gaither Road
Suite E #230
Rockville, MD 20850
North America
|
+33 (0 ) 39030 60 00
Bertin Technologies SAS
Parc d’activités du Pas du Lac
10 bis, avenue Ampère
78 180 Montigny-le-Bretonneux
FRANCE
France
|
www.bertin-instruments.com
Manufacturer |
| Bertin Corporation |
Product Name |
| Coriolis Micro |
Detection Category |
| Biological |
Detection Principle |
| Sample Collection;Molecular; |
Detection Method |
| Medical Countermeasure; |
Application |
| Sample Collection; |
Equipment Type |
| Sample Collection |
Product Synopsis |
| The Coriolis Micro is a microbial air sampler used for bio- contamination control assessment. Through its liquid cyclonic technology, it can collect viral particles in a chosen collection liquid. Coriolis µ samples are compatible with all rapid microbiology techniques such as qPCR or microarrays, and also NGS analysis. Virus concentrations as low as 100 genomes copies/m3 can be detected in collected air samples. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Supporting Documentation |
| Docs: Brochure_Coriolis-Micro_web.pdf; |
Dimensions |
| 8.7 x 13 x14.2 in. (22 x 33 x 36 cm) |
Weight |
| <30 Lbs.; 6.61 Lbs. (3 kg) with battery |
Transportability |
| Person-Portable |
Consumables |
| <$1,000/year; Sterile and non sterile cones, collection buffers, ducted air inlet |
Calibration Schedule |
| Annual |
Communications Interface |
| Wi-Fi |
Expected Operational Life |
| Indefinite |
Other Biological Targets |
| Bacteria, viruses, mold, spores, pollen or toxins |
Sample Introduction |
| Liquid; Particle; Vapor/Gas; |
Sensitivity/Detection Limits |
| copies/mL; 100 genomes copies/m3 |
Total Run Time |
| 10 minutes to 6 hours |
Software Control |
| On-board |
Other Operational Parameters |
| Flow rate 100 to 300 L/min. Collection particle size from 0.5 micro meter. |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |