X-550 XRF

The X-550 handheld XRF analyzer designed to provide non - destructive composition analysis . With a silicon drift detector the X-550 is optimized for sulfidic corrosion. It is designed for applications such as mining, environmental alloy analysis and RoHS applications.

Notify me on updates of this product 

Availability: Commercially Available

Don Sackett
sales@sciaps.com
+1 339 927 9455
2 Constitution Way
Woburn, MA 01801
SciAps Manufacturing & Service
+1 339 927 9455
5452 Aerospace Drive
Laramie, WY 82070
www.sciaps.com
Manufacturer
SciAps, Inc.
Product Name
X-550 XRF
Detection Category
Chemical; Explosives
Detection Principle
Elemental Analysis;
Detection Method
X-ray Fluorescence;
Application
Bulk Analysis;Screening;
Product Model Number
X-550; X-550 Pb
Equipment Type
Instrument
Product Synopsis
The X-550 handheld XRF analyzer designed to provide non - destructive composition analysis . With a silicon drift detector the X-550 is optimized for sulfidic corrosion. It is designed for applications such as mining, environmental alloy analysis and RoHS applications.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
2021
User Feedback Sources
Indifferent/No user feedback
Dimensions
7.25 x 10.5 x 4.5 in ( 18.415 x 26.67 x 11.43 cm)
Weight
<5 Lbs.; 2.8 Ibs (1.3 kg) with battery
Power Requirements
AC/DC Line Power; Lithium Battery; rechargeable
Transportability
Handheld
Ruggedness
None
Operating Conditions
-12 to 54°C (10 to 130°F) at 25% duty cycle
Consumables
<$1,000/year; XRF sample cups
Available Accessories
Test stand, Kickstand
Data Analysis Support Equipment
ProfileBuilder PC Software
Communications Interface
Wi-Fi, Bluetooth, USB, GPS
Expected Operational Life
Indefinite
Shelf Life
>5 years
Other Chemical Targets
Elemental analysis
Number of Library Entries
Standard library contains 500+ grades, no practical size limit. Multiple libraries supported
Adaptability
Yes; manufacturer can add new targets to detector
Sample Introduction
Solid;Liquid;
Sensitivity/Detection Limits
Bulk; %
Known Interferents/Inhibitors
Fluorescence
Start Up Time (From Cold Start To Sample Ready)
<5 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
<5 minutes
Alarm Capability
None
Software Control
On-board; PC
Other Operational Parameters
Detector 20 mm2 silicon drift detector (SDD)
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Reachback Service
Yes
Warranties
Yes
IATA Shipping Restrictions
Yes; Lithium ion battery