Dräger X-act® 7000
The Dräger X-act® 7000 analysis system consists of Dräger MicroTubes and an opto-electronic analysis device to measure gases in the ppb range. To use: insert the Dräger MicroTubes, start measuring, then read out the test result. Based on colorimetric chemical sensor technology. Using the coupler (connector piece), the Dräger X-am® Pump can be attached to the X-act 7000. This allows for carcinogenic and toxic substance testing in the ppb range, in hard-to-reach places like ducts, pipelines or tanks up to a distance of 45 meters (147.6 feet).
Availability: Commercially Available
| Manufacturer |
| Dräger Safety, Inc. |
| Product Name |
| Dräger X-act® 7000 |
| Detection Category |
| Chemical |
| Detection Principle |
| Colorimetric |
| Detection Method |
| Colorimetric |
| Application |
| Gas Analysis; |
| Product Model Number |
| 86 10 800 |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The Dräger X-act® 7000 analysis system consists of Dräger MicroTubes and an opto-electronic analysis device to measure gases in the ppb range. To use: insert the Dräger MicroTubes, start measuring, then read out the test result. Based on colorimetric chemical sensor technology. Using the coupler (connector piece), the Dräger X-am® Pump can be attached to the X-act 7000. This allows for carcinogenic and toxic substance testing in the ppb range, in hard-to-reach places like ducts, pipelines or tanks up to a distance of 45 meters (147.6 feet). |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| Market Entry Date |
| 2020 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 7.68 x 3.35 x 2.76 in (19.5 x 8.5 x 7 cm) |
| Power Requirements |
| Alkaline battery; 5 AA (>10 hours) |
| Transportability |
| Handheld |
| Ruggedness |
| Dust; Waterproof/Resistant; Explosion proof ; IP54 |
| Operating Conditions |
| 0 to 50°C (32 to 122°F), 0 to 95% RH, non-condensing |
| Consumables |
| <$1,000/year; Dräger MicroTubes |
| Available Accessories |
| Dräger X-am® Pump; Coupler, Telescopic probe, Pre-tube holder |
| Communications Interface |
| USB |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| <1 year |
| Unit Cost |
| $3,400.00 |
| Tested For ITF-25 TIC/TIMs |
| Ammonia, Chlorine, Formaldehyde, Sulfur dioxide, hydrochloric acid, hydrocyanic acid, carbon monoxide, ethylene oxide |
| Tested For Explosives |
| Yes |
| Other Chemical Targets |
| Carcinogens and toxic substances, including benzene, mercury, formaldehyde, ammonia, hydrochloric acid, hydrocyanic acid, hydrogen sulfide, toluene, xylene, sulphur dioxide, chlorine, ethylene oxide |
| Number of Library Entries |
| 18 |
| Adaptability |
| No; cannot detect or add new targets |
| Sample Introduction |
| Vapor/Gas; |
| Sensitivity/Detection Limits |
| ppb |
| Start Up Time (From Cold Start To Sample Ready) |
| <30 seconds |
| Response Time (Sample Application To Output) |
| >15 minutes; 5 second - 20 minutes |
| Total Run Time |
| Continuous monitor |
| Software Control |
| On-board |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Warranties |
| Yes |