DeNIRO NIR Flourometer

The DeNIRO NIR fluorometer is a handheld instrument designed for measuring bacterial and enzymatic activity using Detact Diagnostic assays using the Near-Infrared wavelength range.

Notify me on updates of this product 

Availability: Commercially Available

info@detactdiagnostics.com
+44 748 838 7774
Hoge der A-3C
9712AC, Groningen The Netherlands
The Netherlands
www.detactdiagnostics.com
Manufacturer
Detact Diagnostics
Product Name
DeNIRO NIR Flourometer
Detection Category
Biological;
Detection Principle
Molecular;Spectrometry;
Detection Method
Near Infrared;
Application
Laboratory Analysis;Diagnostics;
Equipment Type
Instrument
Product Synopsis
The DeNIRO NIR fluorometer is a handheld instrument designed for measuring bacterial and enzymatic activity using Detact Diagnostic assays using the Near-Infrared wavelength range.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
5.4 x 10 x 2.2 in (13.7 x 25.4 x 5.6 cm)
Weight
<5 Lbs.
Power Requirements
AC/DC Line Power; 100-240 VAC, 1.0A; 12 VDC, 2.5 A input
Transportability
Handheld
Ruggedness
None
Operating Conditions
10 to 40 °C, 20-80% humidity (non-condensing)
Consumables
<$1,000/year; assay tubes
Solvents/Reagents
Substrate, EnzoTact Pro Assay Set, EnzoTact Pro Control Solution
Suggested Routine Maintenance
Daily blanks, surface cleaning with damp cloth, clean touch screen
Available Accessories
DeNIRO Assay Tubes (0.5 mL and 2.0. mL), MySPIN 12 minicentrifuge, Vortex, EnzoTact Pro Assay Set, EnzoTact Pro Control Solution
Data Analysis Support Equipment
Computer
Communications Interface
USB
Shelf Life
>5 years
Other Biological Targets
Bacteria and/or enzymatic activity
Sample Introduction
Liquid;
Start Up Time (From Cold Start To Sample Ready)
<1 minute
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
<5 seconds/sample
Software Control
On-board
Other Operational Parameters
Stores results from up to 1000 samples Dynamic range: 5 orders of magnitude Light source: NIR LED (max ~760 nm) Excitation filter: Near IR 750-769 nm Emission filter: Near IR 800-1250 nm Detector: Photodiodes 300-1000 nm
Training Required
<1 week training
Training Available
Yes
Manuals Available
User's Manual
Warranties
As described by Thermo Fisher Scientific General Terms and Conditions of Sale
Data File Type Format
CSV; Exports data to a USB drive or directly to computer via a USB cable
Please enter contact info.