SIGIS-2
The SIGIS 2 is a scanning imaging remote sensing system based on the combination of an infrared spectrometer with a single element detector and a scanner system. It allows automatic identification, quantification and visualization of gas clouds from long distances. The system measures a selected area and visualizes a chemical image overlaid on a video image as a result of the automatic analysis. SIGIS 2 systems are applied in industrial facility surveillance, environmental applications, atmospheric research, and volcanology and are part of the equipment of emergency response forces around the world. Since the SIGIS 2 is a passive remote sensing system, no external light sources or reflection optics are needed.
Availability: Commercially Available
+1 978 439 9899
Billerica, MA USA
www.bruker.com/optics
|
|
Manufacturer |
| Bruker Corporation |
Product Name |
| SIGIS-2 |
Detection Category |
| Chemical |
Detection Principle |
| Imaging; |
Detection Method |
| Infrared Imaging; |
Application |
| Emergency Response; Screening; |
Equipment Type |
| Instrument |
Product Synopsis |
| The SIGIS 2 is a scanning imaging remote sensing system based on the combination of an infrared spectrometer with a single element detector and a scanner system. It allows automatic identification, quantification and visualization of gas clouds from long distances. The system measures a selected area and visualizes a chemical image overlaid on a video image as a result of the automatic analysis. SIGIS 2 systems are applied in industrial facility surveillance, environmental applications, atmospheric research, and volcanology and are part of the equipment of emergency response forces around the world. Since the SIGIS 2 is a passive remote sensing system, no external light sources or reflection optics are needed. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 46 x 22.8 x 14.4 in (119 x 58 x 36.5 cm) |
Weight |
| >50 Lbs.; 143.3 Lbs. (65 kg) |
Power Requirements |
| AC/DC Line Power; Battery; 110/230 V AC; Battery |
Noise Produced |
| Negligible |
Transportability |
| Mounted |
Ruggedness |
| None |
Operating Conditions |
| 0 to 49°C (32 to 120°F) |
Calibration Schedule |
| No Field Calibration; No calibration to target gas necessary,
automatic radiometric calibration |
Data Analysis Support Equipment |
| Laptop |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Maintenance Cost |
| Minimal |
Tested For Chemical Agents |
| Yes |
Tested For ITF-25 TIC/TIMs |
| Yes |
Sample Introduction |
| Vapor/Gas |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Software Control |
| PC |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Warranties |
| Yes |