Radiacwash™ Spray Mist
Radiacwash™ Spray Mist is a Radiacwash™ Solution packed into a special high pressure mist applicator. When the activator is depressed, over 200 lb of pressure is created at the nozzle. The pressure misting effect allows Radiacwash™ to penetrate around and under contaminants and lift them off the surface into solution to be wiped up and disposed.
Availability: Commercially Available
Manufacturer |
| Biodex Medical Systems |
Product Name |
| Radiacwash™ Spray Mist |
Detection Category |
| Radiological/Nuclear |
Detection Method |
| PPE/Decon |
Application |
| Decontamination; |
Equipment Type |
| Decontamination |
Product Synopsis |
| Radiacwash™ Spray Mist is a Radiacwash™ Solution packed into a special high pressure mist applicator. When the activator is depressed, over 200 lb of pressure is created at the nozzle. The pressure misting effect allows Radiacwash™ to penetrate around and under contaminants and lift them off the surface into solution to be wiped up and disposed. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
Market Entry Date |
| 1951 |
User Feedback Sources |
| Indifferent/No user feedback |
Weight |
| <5 lbs. |
Power Requirements |
| None |
Transportability |
| Handheld |
Operating Conditions |
| > 0°C (32°F) |
Shelf Life |
| <5 years; 2 years when canister remains unopened and sealed; 3 months once opened |
Unit Cost |
| $12.00 (1 liter bottle) |
Active Mechanism |
| Mass effect ion displacement |
Water/Oil Based |
| Water based |
Effective Against |
| Radiological (specifically created for the fast and safe removal of the entire spectrum of nuclidic radioactivity) |
Environmental Class |
| Environmentally friendly, biodegradable |
Form |
| Spray |
Hazardous Residue or Runoff |
| No |
Live Agent Tested |
| Yes |
Number of Operators Required |
| 1 |
Preparation Time |
| < 5 seconds |
Product Use |
| Can be used safely on all surfaces including skin, cloth, all metals, glass, floors, walls, leather, rubber, porcelain, plastic, laboratory instruments, utensils and equipment |
Sensitive or Electronic Use |
| No |
Size of Application |
| Varies |
Surface Contact Time |
| < 10 seconds |
Tested By |
| EPA, Lawrence Livermore Laboratory |
Volume of Decon Solution Applicator can hold |
| 1 liter |
Other Operational Parameters |
| Radiacwash™ has a pH of 5, less than .008% Halides, contains no phosphates, chromates, silicates, enzymes, borates, aluminates, carbonates, and inert fillers that can interfere with sensitive analytical procedures |
Training Required |
| <1 hour training |
Training Available |
| No |
Manuals Available |
| Yes |
Warranties |
| Yes, Limited |