Pac® 8000

The Pac® 8000 is a handheld personal single-gas detection device which detects hazardous concentrations of twenty nine different gases, including special gases like NO2, O3 or COCl2.

Notify me on updates of this product 

Availability: Commercially Available

+1-800-437-2437
7256 S. Sam Houston W Pkwy. Suite 100
Houston, TX 77085
USA
+49 451 8837
Moislinger Allee 53-72
23575 Lübeck
Germany
www.draeger.com
Manufacturer
Dräger Safety, Inc.
Product Name
Pac® 8000
Detection Category
Chemical
Detection Principle
Sensors
Detection Method
Electrochemical Detection
Application
Gas Analysis;Emergency Response;
Equipment Type
Instrument
Product Synopsis
The Pac® 8000 is a handheld personal single-gas detection device which detects hazardous concentrations of twenty nine different gases, including special gases like NO2, O3 or COCl2.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
2.5 x 3.3 x 0.8 in (64 x 84 x 20 mm)
Weight
<1 Lb.; 3.7 ounces (106 g)
Power Requirements
Lithium Battery; 2 years
Noise Produced
90 dB
Transportability
Pocket Size
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP68
Operating Conditions
-30 to 55 °C (-22 to 131 °F), 10 to 90% relative humidity
Consumables
<$1,000/year; Sensing element, water & dust filters
Calibration Schedule
Calibrations performed at Dräger X-dock® calibration station, and automatic bump tests
Suggested Routine Maintenance
Minimal
Available Accessories
Belt Clip, USB cable
Data Analysis Support Equipment
PC, Software
Communications Interface
USB
Expected Operational Life
Indefinite
Shelf Life
>5 years
Maintenance Cost
Minimal
Other Chemical Targets
Carbon dioxide (CO2), chlorine gas (Cl2), hydrogen cyanide (HCN), ammonia (NH3), nitrogen dioxide (NO2), Ozone (O3), phosphine (PH3), phosgene (COCl2), and organic vapors (OV or OV-A).
Adaptability
No; cannot detect or add new targets
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
ppm; O3 0.02 ppm, COCl2 0.01 ppm, NO2 0.04 ppm
Start Up Time (From Cold Start To Sample Ready)
Seconds
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous monitor
Alarm Capability
Audible, Visual, Vibrational. User defined thresholds.
Software Control
On-board
Training Required
<1 day training
Training Available
No
Manuals Available
Yes
Reachback Service
No
Warranties
Yes
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: