AccuRad™ PRD

The AccuRad™ PRDA is a personal radiation detector designed for law enforcement, fire rescue, and other emergency responders to detect and interdict nuclear and radioactive materials. It also provides dose measurement and alarming capabilities for event response.

Notify me on updates of this product 

Availability: Commercially Available

Carol McGowan
Homeland Security and Defense Sales Manager
cmcgowan@mirion.com
+1 770 329 3228
5000 Highlands Parkway Suite 150
Smyrna, GA 30082
USA
www.mirion.com
Manufacturer
Mirion Technologies
Product Name
AccuRad™ PRD
Detection Category
Radiological/Nuclear;
Detection Principle
Scintillation Detectors;
Detection Method
Scintillation Detectors;
Application
Personal Radiation Detectors;
Equipment Type
Instrument
Product Synopsis
The AccuRad™ PRDA is a personal radiation detector designed for law enforcement, fire rescue, and other emergency responders to detect and interdict nuclear and radioactive materials. It also provides dose measurement and alarming capabilities for event response.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: accurad_spec_sheet_b.pdf;
Dimensions
4.25 x 2.4 x 1.4 in (108 x 61 x 36 cm) without clip
Weight
<1 Lb.; 7 oz. (200 g) including clip
Power Requirements
Alkaline Battery; Two AA batteries (900 hours)
Noise Produced
Audio alarm: 85 dB(A) at 30 cm (11.8 in.)
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP67
Operating Conditions
-20 to 60 °C (-4 to 140 °F)
Consumables
None
Suggested Routine Maintenance
None
Available Accessories
AA alkaline batteries, quick guide, spare clip, USB C earphones, clip, battery cover, Radiation safety training modules
Data Analysis Support Equipment
SpirVIEW Mobile command center software
Communications Interface
Bluetooth and USB-C
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$1,350.00
Maintenance Cost
None
Radiological Targets
Radionuclides
Number of Library Entries
ANSI N42
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
µSv; µR; 50 µrem/h (0.5 µSv/h)
Start Up Time (From Cold Start To Sample Ready)
Seconds to minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); 2 seconds
Total Run Time
Continuous monitor
Alarm Capability
Audible and visual
Software Control
On-board
Other Operational Parameters
Detector: CsI(Tl), Silicon diode, Energy range: 25 keV to 3 MeV; Dose Range: up to 1000 rem/h (10 Sv/h)
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
Yes
Data File Type Format
ANSI N42.42 files
Please enter contact info.