PM1401 PRD Series

Personal radiation detector PM1401MA is designed for detecting of gamma radiation sources. Due to its hermetic and shockproof case and the LCD screen fluorescent backlight, instrument can be used in extreme and harsh environments. For work in difficult-to-access areas telescopic extension tube is provided. PRD has audible, visual and vibrating alarms, records and stores up to 1000 events in non-volatile memory and transmits data to a PC via IR channel. The MA and GNA models have a CS(Ti) detector. The GNA also has a 3He detector.

Notify me on updates of this product 

Availability: Commercially Available

James Mehalchick
info@polimaster.us
+1 703 525 5075
44873 Falcon Place Suite 128
Sterling, VA 20166
USA
www.polimaster.com
Manufacturer
Polimaster, Inc.
Product Name
PM1401 PRD Series
Detection Category
Radiological/Nuclear
Detection Principle
Scintillation Detectors;
Detection Method
Scintillation Detectors;
Application
Personal Radiation Detectors;
Product Model Number
PM1401MA, MP1401GNA
Equipment Type
Instrument
Product Synopsis
Personal radiation detector PM1401MA is designed for detecting of gamma radiation sources. Due to its hermetic and shockproof case and the LCD screen fluorescent backlight, instrument can be used in extreme and harsh environments. For work in difficult-to-access areas telescopic extension tube is provided. PRD has audible, visual and vibrating alarms, records and stores up to 1000 events in non-volatile memory and transmits data to a PC via IR channel. The MA and GNA models have a CS(Ti) detector. The GNA also has a 3He detector.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
4.3 x 2.25 x 1.25 in (11 x 5.7 x 3.2 cm)
Weight
<1 lb.; 0.7 lbs. (320 g)
Power Requirements
Alkaline Battery; AA Battery (1,000 hours)
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP65
Operating Conditions
-30 to 50°C (-22 to 122°F), <95% RH non-condensing
Consumables
None
Calibration Schedule
None
Suggested Routine Maintenance
None
Available Accessories
None
Data Analysis Support Equipment
Polimaster proprietary software, can be used for radionuclide identification with PC connection
Communications Interface
IRDA, Bluetooth (model MB)
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$1,200.00
Maintenance Cost
None
Radiological Targets
Gamma, neutron
Adaptability
No; cannot detect or add new targets
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
cps; µR
Start Up Time (From Cold Start To Sample Ready)
Seconds to minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); 0.25 seconds
Total Run Time
Continuous
Alarm Capability
Audible, visual, vibrational
Software Control
On-board, PC
Other Operational Parameters
Detector: Csl(TI, Energy Range; 0.06 to 3.0 MeV, Dose Rate; 0.1 µSv/h to 70 µSv/h. Data storage: up to 1,000 events
Training Required
<1 day training
Training Available
Yes
Manuals Available