Dosimeters are designed to work in extreme conditions to provide real-time environmental radiation monitoring. They have two independent alarm thresholds within all dose equivalent rate (DER ) and dose equivalent (DE ) measurement ranges. Audible and visual alarms alert users when the preset thresholds have been exceeded. Applications for emergency service, customs and border patrol, fire rescue and police, medical professionals, and civil defense.

Notify me on updates of this product 

Availability: Commercially Available

James Mehalchick
info@polimaster.us
+1 703 525 5075
44873 Falcon Place Suite 128
Sterling, VA 20166
USA
www.polimaster.com
Manufacturer
Polimaster, Inc.
Product Name
PM1603 series
Detection Category
Radiological/Nuclear
Detection Principle
Geiger-Muller Detectors;
Detection Method
Geiger-Muller Detectors;
Application
Dosimeters;
Product Model Number
PM1603A, PM1603B (wrist) PM1604A, PM1604B (breast pocket)
Equipment Type
Instrument
Product Synopsis
Dosimeters are designed to work in extreme conditions to provide real-time environmental radiation monitoring. They have two independent alarm thresholds within all dose equivalent rate (DER ) and dose equivalent (DE ) measurement ranges. Audible and visual alarms alert users when the preset thresholds have been exceeded. Applications for emergency service, customs and border patrol, fire rescue and police, medical professionals, and civil defense.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
1.96 x 2.2 x 0.75 in (5.0 x 5.6 x 1.9 cm) wrist 1.96 x 3.54 x 0.75 in (5.0 x 9.0 x 1.9 cm) pocket with clip
Weight
<1 lb.; 0.2 lbs. (85 g) with battery
Power Requirements
Lithium Battery; CR 2032 battery (~9 months)
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP67
Operating Conditions
-20 to 70°C (-4 to 158°F) < 98 % RH
Consumables
None
Solvents/Reagents
None
Suggested Routine Maintenance
None
Available Accessories
None
Data Analysis Support Equipment
None
Communications Interface
IrDA
Expected Operational Life
Indefinite
Shelf Life
>5 years
Maintenance Cost
None
Radiological Targets
Gamma, X-ray
Adaptability
No; cannot detect or add new targets
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
µSv
Start Up Time (From Cold Start To Sample Ready)
Seconds to minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous monitor
Alarm Capability
Audible, visual
Software Control
On-board
Other Operational Parameters
Energy Range: 0.048 to 3 MeV (wrist), 0.048 to 6 MeV (pocket clip)
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
Yes
Please enter contact info.