Instruments provide measurement of dose and dose equivalent rate of continuous and pulsed X-ray and gamma radiation. Audible, visual, and vibrational alarms warn user when threshold levels are exceeded. PM1610-01/PM1610A-01 can be used with wireless readers in compliance with ISO 15693. Recommended for medical professionals, first responders, border patrol and radiological laboratories.

Notify me on updates of this product 

Availability: Commercially Available

James Mehalchick
info@polimaster.us
+1 703 525 5075
44873 Falcon Place Suite 128
Sterling, VA 20166
USA
www.polimaster.com
Manufacturer
Polimaster, Inc.
Product Name
PM1610 series
Detection Category
Radiological/Nuclear
Detection Principle
Geiger-Muller Detectors;
Detection Method
Geiger-Muller Detectors;
Application
Dosimeters;
Product Model Number
PM1610, PM1610A, PM1610-01, PM1610A-01
Equipment Type
Instrument
Product Synopsis
Instruments provide measurement of dose and dose equivalent rate of continuous and pulsed X-ray and gamma radiation. Audible, visual, and vibrational alarms warn user when threshold levels are exceeded. PM1610-01/PM1610A-01 can be used with wireless readers in compliance with ISO 15693. Recommended for medical professionals, first responders, border patrol and radiological laboratories.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
2.28 x 2.28 x 0.71 in (5.8 x 5.8 x 1.8 cm)
Weight
<1 lb.; 0.15 lbs. (70 g)
Power Requirements
Lithium Battery; Built in re-chargeable battery via USB
Transportability
Pocket Size
Ruggedness
Waterproof/Resistant; Dust; IP65
Operating Conditions
-20 ± 50°C (-4 to 122°F)
Consumables
None
Solvents/Reagents
None
Suggested Routine Maintenance
None
Available Accessories
None
Data Analysis Support Equipment
None
Communications Interface
USB
Expected Operational Life
Indefinite
Shelf Life
>5 years
Maintenance Cost
None
Radiological Targets
Gamma, X-ray
Adaptability
No; cannot detect or add new targets
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
µSv
Start Up Time (From Cold Start To Sample Ready)
Seconds to minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous monitor
Alarm Capability
Audible, Visual, Vibrational
Software Control
On-board
Other Operational Parameters
Energy Range: 20 keV to 10 MeV. Automatic data logging of 75,00 data points.
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
Yes