MiniTRACE

MiniTRACE gamma is a dose rate meter designed to improve the safety of workers in control areas of nuclear power plants, reprocessing facilities, research centers and hospitals. All measurement values can be read with the infrared interface, using the communication kit. Optionally, a GPS module is available. The radio versions MiniTRACE gamma S10R and S100R are equipped with a wireless UHF transmission module.

Notify me on updates of this product 

Availability: Commercially Available

+33 (0)1 39 30 60 00
10 bis, avenue Ampère
78 180 Montigny-le-Bretonneux
France
+1 844 7BERTIN
2096 Gaither Road, Suite # 230
Rockville, MD 20850
USA
www.bertin-instruments.com
Manufacturer
Bertin Corporation
Product Name
MiniTRACE
Detection Category
Radiological/Nuclear
Detection Principle
Geiger-Muller Detectors;
Detection Method
Geiger-Muller Detectors;
Application
Personal Radiation Detectors;
Product Model Number
S10R and S100R
Equipment Type
Instrument
Product Synopsis
MiniTRACE gamma is a dose rate meter designed to improve the safety of workers in control areas of nuclear power plants, reprocessing facilities, research centers and hospitals. All measurement values can be read with the infrared interface, using the communication kit. Optionally, a GPS module is available. The radio versions MiniTRACE gamma S10R and S100R are equipped with a wireless UHF transmission module.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Weight
<5 lbs.
Power Requirements
Alkaline Battery; 2 mignon batteries (type: LR6, AA, MN 1500) 1.5V (2,000 hours)
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP44
Operating Conditions
-20 to 50 °C (- 4 to 122 °F)
Consumables
None
Solvents/Reagents
None
Suggested Routine Maintenance
None
Available Accessories
None
Communications Interface
GPS optional
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$1,000.00
Maintenance Cost
None
Radiological Targets
Gamma, X-ray
Adaptability
No; cannot detect or add new targets
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
µSv
Start Up Time (From Cold Start To Sample Ready)
Seconds to minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous monitor
Alarm Capability
Audible and visual
Software Control
On-board
Other Operational Parameters
Data storage: up to 650 measurements, Energy Range: 42 keV to 2.8 MeV, Display Range: 10 nSv/h to 10 mSv/h
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
Yes
Please enter contact info.