RAE Systems Gas Detection Tubes
RAE Systems Gas Detector Tubes provide on-the-spot measurement of specific toxic and combustible substances. The hand pump features a spring-less piston to accurately draw 50 and 100cc samples. The single-use colorimetric gas detection tubes change color in direct correlation to the concentration of gas present. No calibration is required, and the ergonomic pump can be used even with multiple layers of gloves.
Availability: Commercially Available
| Manufacturer |
| Honeywell Analytics |
| Product Name |
| RAE Systems Gas Detection Tubes |
| Detection Category |
| Chemical |
| Detection Principle |
| Colorimetric; |
| Detection Method |
| Colorimetric; |
| Application |
| Gas Analysis; Emergency Response; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| RAE Systems Gas Detector Tubes provide on-the-spot measurement of specific toxic and combustible substances. The hand pump features a spring-less piston to accurately draw 50 and 100cc samples. The single-use colorimetric gas detection tubes change color in direct correlation to the concentration of gas present. No calibration is required, and the ergonomic pump can be used even with multiple layers of gloves. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Positive user feedback |
| Weight |
| <1 Lb.; 1 oz. per tube (29 g) |
| Power Requirements |
| None |
| Transportability |
| Pocket Size |
| Ruggedness |
| None |
| Consumables |
| None |
| Solvents/Reagents |
| None |
| Calibration Schedule |
| None |
| Suggested Routine Maintenance |
| None |
| Available Accessories |
| LP-1200 hand pump |
| Expected Operational Life |
| Single use item |
| Shelf Life |
| <5 years; 1 to 3 years depending upon detector tube |
| Unit Cost |
| $100.00 |
| Maintenance Cost |
| None |
| Tested For ITF-25 TIC/TIMs |
| Acetone, amines, ammonia, benzene, butadiene, n-butane, carbon dioxide, carbon monoxide, chlorine, chlorine dioxide, diesel & jet fuel, ethanol, formaldehyde, gasoline, hydrocarbons, hydrogen chloride, hydrogen cyanide, hydrogen fluoride, hydrogen sulfide, MEK, mercaptans, methyl bromide, nitric acid, nitrogen dioxide, ozone, phenol, phosphine, sulfur dioxide, toluene, trichloroethylene, vinyl chloride, xylene |
| Adaptability |
| No; cannot detect or add new targets |
| Sample Introduction |
| Vapor/Gas; |
| Sensitivity/Detection Limits |
| ppm |
| Known Interferents/Inhibitors |
| Cross-interferences are listed in the operating instructions for each analyte tube |
| False Positive Rates |
| <10% |
| False Negative Rates |
| 10% |
| Start Up Time (From Cold Start To Sample Ready) |
| Immediate |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds); < 5 seconds |
| Total Run Time |
| < 1 minute |
| Alarm Capability |
| Visual |
| Other Operational Parameters |
| Users may have difficulty interpreting color changes at threshold concentrations. |
| Training Required |
| <1 hour training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Reachback Service |
| No |
| Warranties |
| None |
| ITAR/EAR Export Regulations |
| No |
| IATA Shipping Restrictions |
| No |