Honeywell BW™ Series

The Honeywell BW Series gas detectors are handheld, rugged single and multi-gas personal devices. The Ultra model is a 5-gas detector. The Clip4, MicroClip, Max XT, Flex, and Icon are 4-gas, the BW Solo is a 1-gas detector.

Notify me on updates of this product 

Availability: Commercially Available

Tom Kochevar
detectgas@honeywell.com
+1 877 723 2878
3775 North First Street
San Jose, CA 65134
USA
www.honeywellanalytics.com
Manufacturer
Honeywell Analytics
Product Name
Honeywell BW™ Series
Detection Category
Chemical;
Detection Principle
Sensors;
Detection Method
Electrochemical Detection;
Application
Gas Analysis;Screening;
Product Model Number
Ultra, Clip4, MicroClip, Solo, Icon, Max XT II, Flex
Equipment Type
Instrument
Product Synopsis
The Honeywell BW Series gas detectors are handheld, rugged single and multi-gas personal devices. The Ultra model is a 5-gas detector. The Clip4, MicroClip, Max XT, Flex, and Icon are 4-gas, the BW Solo is a 1-gas detector.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: BW Ultra Datasheet.pdf;
Dimensions
Ultra: 5.8 x 3.3 x 1.6 in. (14.8 x 8.5 x 4.0 cm)
Weight
<1 Lb.; Ultra; 0.9 Lb. (411 g)
Power Requirements
Lithium Battery; 18 hours
Noise Produced
95 dB
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP66/68
Operating Conditions
-20 to 50°C (-4 to 122°F), 5 to 95% RH
Consumables
<$1,000/year; Sensors
Solvents/Reagents
None
Calibration Schedule
Activated detectors automatically perform one internal diagnostic test every 24 hours (sensors, battery, and circuitry).
Suggested Routine Maintenance
None
Data Analysis Support Equipment
INTELLIDOX Docking System
Communications Interface
Bluetooth
Expected Operational Life
5 years
Shelf Life
>5 years
Maintenance Cost
None
Tested For ITF-25 TIC/TIMs
HCN
Other Chemical Targets
Hydrogen sulfide, carbon monoxide, oxygen, carbon dioxide, sulfur dioxide, ammonia, hydrogen, chlorine, nitrogen dioxide, nitrogen oxide
Adaptability
No; cannot detect or add new targets
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
ppm
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous
Alarm Capability
Audible, visual, vibrational
Software Control
On-board
Other Operational Parameters
Logging: 30 alarm events and 10 bump events, 45 days based on 8 hour shifts every 15 seconds logging
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
Instrument: 3 years, Sensors: 3 years (2 years NH3, 1 year PID and Cl2), Battery: 2 years
IATA Shipping Restrictions
Yes; lithium ion battery
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: