Honeywell BW™ Series
The Honeywell BW Series gas detectors are handheld, rugged single and multi-gas personal devices. The Ultra model is a 5-gas detector. The Clip4, MicroClip, Max XT, Flex, and Icon are 4-gas, the BW Solo is a 1-gas detector.
Availability: Commercially Available
Manufacturer |
| Honeywell Analytics |
Product Name |
| Honeywell BW™ Series |
Detection Category |
| Chemical; |
Detection Principle |
| Sensors; |
Detection Method |
| Electrochemical Detection; |
Application |
| Gas Analysis;Screening; |
Product Model Number |
| Ultra, Clip4, MicroClip, Solo, Icon, Max XT II, Flex |
Equipment Type |
| Instrument |
Product Synopsis |
| The Honeywell BW Series gas detectors are handheld, rugged single and multi-gas personal devices. The Ultra model is a 5-gas detector. The Clip4, MicroClip, Max XT, Flex, and Icon are 4-gas, the BW Solo is a 1-gas detector. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Supporting Documentation |
| Docs: BW Ultra Datasheet.pdf; |
Dimensions |
| Ultra: 5.8 x 3.3 x 1.6 in. (14.8 x 8.5 x 4.0 cm) |
Weight |
| <1 Lb.; Ultra; 0.9 Lb. (411 g) |
Power Requirements |
| Lithium Battery; 18 hours |
Noise Produced |
| 95 dB |
Transportability |
| Handheld |
Ruggedness |
| Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP66/68 |
Operating Conditions |
| -20 to 50°C (-4 to 122°F), 5 to 95% RH |
Consumables |
| <$1,000/year; Sensors |
Solvents/Reagents |
| None |
Calibration Schedule |
| Activated detectors automatically perform one internal diagnostic test every 24 hours (sensors, battery, and circuitry). |
Suggested Routine Maintenance |
| None |
Data Analysis Support Equipment |
| INTELLIDOX Docking System |
Communications Interface |
| Bluetooth |
Expected Operational Life |
| 5 years |
Shelf Life |
| >5 years |
Maintenance Cost |
| None |
Tested For ITF-25 TIC/TIMs |
| HCN |
Other Chemical Targets |
| Hydrogen sulfide, carbon monoxide, oxygen, carbon dioxide, sulfur dioxide, ammonia, hydrogen, chlorine, nitrogen dioxide, nitrogen oxide |
Adaptability |
| No; cannot detect or add new targets |
Sample Introduction |
| Vapor/Gas; |
Sensitivity/Detection Limits |
| ppm |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| Continuous |
Alarm Capability |
| Audible, visual, vibrational |
Software Control |
| On-board |
Other Operational Parameters |
| Logging: 30 alarm events and 10 bump events, 45 days based on 8 hour shifts every 15 seconds logging |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Warranties |
| Instrument: 3 years, Sensors: 3 years (2 years NH3, 1 year PID and Cl2), Battery: 2 years |
IATA Shipping Restrictions |
| Yes; lithium ion battery |