Niton™ XL2 Plus

The Niton™ XL2 Plus is a handheld XRF analyzer. It can identify pure metals and alloys, or obtain geochemical data. the Niton XL2 Plus provides operators the ability to scan a broad range of materials in one versatile analyzer. Contains a Silicon Drift Detector (SDD).

Notify me on updates of this product 

Availability: Commercially Available

Dan Davis
Product Manager
daniel.davis2@thermofisher.com
978-513-9717
2 Radcliff Road
Tewksbury, MA 01876
USA
John Tiggas
jtiggas@alphasi.com
+1 952 929 1134
www.thermoscientific.com
Manufacturer
Thermo Fisher Scientific, Inc.
Product Name
Niton™ XL2 Plus
Detection Category
Chemical; Explosives
Detection Principle
Elemental Analysis;
Detection Method
X-ray Fluorescence;
Application
Bulk Analysis;Screening;Forensics;
Equipment Type
Instrument
Product Synopsis
The Niton™ XL2 Plus is a handheld XRF analyzer. It can identify pure metals and alloys, or obtain geochemical data. the Niton XL2 Plus provides operators the ability to scan a broad range of materials in one versatile analyzer. Contains a Silicon Drift Detector (SDD).
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
2019
User Feedback Sources
Indifferent/No user feedback
Dimensions
10 x 10.8 x 3.9 in (25.6 x 27.5 x 10 cm)
Weight
<5 lbs.; 3.4 lbs. (1.53 kg)
Power Requirements
AC/DC Line Power; Lithium Battery; 7.4V lithium-ion battery, or 12V DC, 3A, 36W power supply
Noise Produced
Negligible
Transportability
Handheld
Ruggedness
Waterproof/Resistant; Dust; IP54
Operating Conditions
-10 to 50 °C (14 to 122°F), 0 to 80% RH non-condensing
Consumables
<$1,000/year; Sample cups
Solvents/Reagents
None
Suggested Routine Maintenance
Minimal
Available Accessories
Belt holster, safety lanyard, PC connection cables, Portable test stand, mobile test stand, field mate test stand, soil guard
Data Analysis Support Equipment
Niton Data Transfer (NDT) PC software
Communications Interface
USB, Bluetooth, RS-232
Expected Operational Life
Indefinite
Shelf Life
>5 years
Maintenance Cost
Minimal
Other Chemical Targets
Elemental analysis
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Solid;
Sensitivity/Detection Limits
%; ppm
Start Up Time (From Cold Start To Sample Ready)
< 10 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
< 2 minutes
Alarm Capability
None
Software Control
On-board, PC
Other Operational Parameters
Elemental Rage: Mg-U, Memory Storage: 10,000 readings with spectra, CCD micro camera, 8mm spot size
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Reachback Service
Yes
Warranties
Yes
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: