RDS-100P

The RDS-100P Radiation Detection System includes Time-To-Count technique to provide linearity over entire dynamic dose rate range; no compensation for high levels necessary. Multiple smart probe options are available: beta pancake, X-ray, alpha or µR probe.

Notify me on updates of this product 

Availability: Commercially Available

Carol McGowan
Homeland Security and Defense Sales Manager
cmcgowan@mirion.com
+1 770 329 3228
5000 Highlands Parkway Suite 150
Smyrna, GA 30082
Americas
smy-sales@mirion.com
+1 770 432 2744
www.mirion.com
Manufacturer
Mirion Technologies
Product Name
RDS-100P
Detection Category
Radiological/Nuclear
Detection Principle
Geiger-Muller Detectors;
Detection Method
Geiger-Muller Detectors;
Application
Dosimeters;Personal Radiation Detectors;
Product Model Number
RDS-100P
Equipment Type
Instrument
Product Synopsis
The RDS-100P Radiation Detection System includes Time-To-Count technique to provide linearity over entire dynamic dose rate range; no compensation for high levels necessary. Multiple smart probe options are available: beta pancake, X-ray, alpha or µR probe.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
4.1 x 1.81 x 7.56 in (10.4 x 4.8 x 19.2 cm)
Weight
<5 lbs.; 2.42 lbs. (1.11 kg)
Power Requirements
Alkaline Battery; Three standard 9 V BA-3090 cells (100 hours)
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; Vibration/Shock; Mil-STD-810, intrinsically safe
Operating Conditions
-40 to 50 °C (-40 to 122 °F), 0 to 95% RH
Consumables
None
Solvents/Reagents
None
Suggested Routine Maintenance
None
Available Accessories
Carrying case, headset, test sample, pouch with strap
Data Analysis Support Equipment
None
Communications Interface
RS-232
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$14,200.00
Maintenance Cost
None
Radiological Targets
Beta, Gamma Optional: Alpha, X-ray
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
mR; Beta Dose Rate – 0.01 mR/h to 5 R/hr. Gamma Dose Rate – 0.01 mR/h to 999 R/hr.
Known Interferents/Inhibitors
Not affected by EMI
Response Time (Sample Application To Output)
Continuous (<30 seconds); 1 to 2 seconds
Total Run Time
Continuous
Alarm Capability
Audible, Visual
Software Control
On-board, PC
Other Operational Parameters
Provides dose rate readout in units of mR/h and count rates in CPM, µCi/m2 or DPM/100 cm2 (probe dependant)
Training Required
<1 day training
Training Available
No
Manuals Available
Yes
Reachback Service
No
Data File Type Format
None
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: