PKI 8240

The PKI 8240 features a digital multi-channel analyzer, amplifier, high voltage power supply and embedded memory. Standard model includes an integrated 137CS source of about 500 Bq (15nCi) for calibration and stabilization. Optionally a 3He neutron detector can be installed.

Notify me on updates of this product 

Availability: Commercially Available

Peter Klüver
Managing director
information@pki-electronic.com
+49 (0)4154 98 96 32
Großenseer Str. 17
22952 Lütjensee / Hamburg
Germany
www.pki-electronic.com
Manufacturer
PKI Electronic Intelligence
Product Name
PKI 8240
Detection Category
Radiological/Nuclear;
Detection Principle
Scintillation Detectors;Helium 3 Detectors;
Detection Method
Scintillation Detectors;Helium 3 Detectors;
Application
Dosimeters;Personal Radiation Detectors;
Equipment Type
Instrument
Product Synopsis
The PKI 8240 features a digital multi-channel analyzer, amplifier, high voltage power supply and embedded memory. Standard model includes an integrated 137CS source of about 500 Bq (15nCi) for calibration and stabilization. Optionally a 3He neutron detector can be installed.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: PKI 8240 Spec Sheet.pdf;
Dimensions
10 x 3.7 x 3.2 in (25.5 x 9.3 x 8.1 cm)
Weight
<5 lbs.; 2.75 lbs. (1.25 kg) incl. batteries and NaI(Tl) detector
Power Requirements
NiMH Battery; 2500 mAH NiMH rechargeable (10 hours)
Transportability
Handheld
Operating Conditions
-15 to 55°C (5 to 131°F)
Consumables
None
Solvents/Reagents
None
Calibration Schedule
Automatic calibration
Suggested Routine Maintenance
None
Available Accessories
AC adaptor for stationary use and recharging power pack plus, RS232 and USB cables and connector box, holster, carrying case, optionally: earphones. 3He detector.
Data Analysis Support Equipment
None
Communications Interface
RS232, USB
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$60,000.00
Maintenance Cost
None
Radiological Targets
Gamma, neutron
Adaptability
No; cannot detect or add new targets
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
cps
Start Up Time (From Cold Start To Sample Ready)
Immediate
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous
Software Control
On-board
Other Operational Parameters
Detector type: NaI(Tl) for gamma, 3He for neutron, Resolution: 7% to 7.5% at 662 keV, Throughput rate: > 100.000 cps, Energy range: 15 kV to 3 MV
Training Required
<1 day training
Training Available
No
Manuals Available
Yes
Reachback Service
No
Warranties
1 year
Please enter contact info.