H150 and H150E Handheld Trace Detectors

The H150 and H150E are a handheld trace detectors. The 150E model includes explosives and narcotics. With rapid clear down and other features that minimize system contamination, the units is ready for the next sample within seconds, even after a positive detection. The presence of a threat is indicated by both visible and/or audible alarms, with the substance identification clearly displayed. The H150s design includes a non- radioactive ion mobility spectrometry technology, so there are no associated certifications, licensing, inspection, testing or decommissioning costs normally associated with systems that contain radioactive materials.

Notify me on updates of this product 

Availability: Commercially Available

+1 855 9 LEIDOS (534 367)
www.leidos.com
Manufacturer
Leidos
Product Name
H150 and H150E Handheld Trace Detectors
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry;
Detection Method
Ion Mobility Spectrometry;
Application
Emergency Response;Trace Analysis;
Product Model Number
H150, H150E
Equipment Type
Instrument
Product Synopsis
The H150 and H150E are a handheld trace detectors. The 150E model includes explosives and narcotics. With rapid clear down and other features that minimize system contamination, the units is ready for the next sample within seconds, even after a positive detection. The presence of a threat is indicated by both visible and/or audible alarms, with the substance identification clearly displayed. The H150s design includes a non- radioactive ion mobility spectrometry technology, so there are no associated certifications, licensing, inspection, testing or decommissioning costs normally associated with systems that contain radioactive materials.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
6 x 18 x 8.5 in (15.1 x 45.7 x 21.6 cm)
Weight
<30 lbs.; 11 lbs (5kg)
Power Requirements
Lithium Battery; AC/DC Line Power; Li-ion battery, (hot swappable), 100-240 V AC, 47-63Hz 2A
Transportability
Handheld
Operating Conditions
-10 to 55°C (14 to 131°F) < 95% RH,
Consumables
<$1,000/year; Molecular sieve drying agent, sample traps
Calibration Schedule
Fully automated internal calibration
Suggested Routine Maintenance
Cleaning and desiccant replacement as required
Available Accessories
Sample wand, spare batteries, battery charger, printing kit
Data Analysis Support Equipment
4.3in high-resolution touch display, keyboard, monitor, sample wand
Expected Operational Life
10 years
Shelf Life
>5 years
Unit Cost
$25,900.00
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Wide variety of explosives (military, commercial, HME's)
Tested For Narcotics
Yes
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Liquid;Solid;Vapor/Gas;
Sensitivity/Detection Limits
ng; 1 to 50 ng (narcotics)
False Positive Rates
Low
False Negative Rates
Low
Start Up Time (From Cold Start To Sample Ready)
< 30 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); 8 to 30 seconds
Total Run Time
< 30 minutes
Alarm Capability
Audible and visual
Software Control
On-board, PC
Training Required
<1 day training
Manuals Available
Yes
Approved Vendors
Security Detection