IDenta Drug and Explosives Test Kits

The IDentacorp identification tests are individual colorimetric tests for each specific drug or explosive target. The adhesive tip picks up micro-particles and is protected from contamination. The reaction chemicals are contained safely in a hard plastic shell and remain locked inside the test unit to prevent any spills. Can be purcahsed in a Kit of 20 also.

Notify me on updates of this product 

Availability: Commercially Available

info@identacorp.com
+1 855 5IDENTA
3501 Keyser Avenue
Hollywood, FL 33021
USA
+972 2 5872220
Israel
www.indenta-corp.com
Manufacturer
IDenta Corp.
Product Name
IDenta Drug and Explosives Test Kits
Detection Category
Chemical; Explosives
Detection Principle
Colorimetric;
Detection Method
Colorimetric;
Application
Emergency Response;Screening;
Product Model Number
Drugs: IDT0101-20 Explosives: IDT0102-20
Equipment Type
Instrument
Product Synopsis
The IDentacorp identification tests are individual colorimetric tests for each specific drug or explosive target. The adhesive tip picks up micro-particles and is protected from contamination. The reaction chemicals are contained safely in a hard plastic shell and remain locked inside the test unit to prevent any spills. Can be purcahsed in a Kit of 20 also.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
1.9 x 3.7 x 1 in (5.0 x 9.5 x 2.5 cm)
Weight
<1 lb.; 0.09 lbs (40 g)
Power Requirements
None
Transportability
Pocket Size
Operating Conditions
Operates in all conditions
Consumables
None
Solvents/Reagents
Yes
Available Accessories
Snipper, Aerochamber sniffer, carrying pouch
Expected Operational Life
Single use item
Shelf Life
<5 years; 3 years
Unit Cost
$85.00
Tested For ITF-25 TIC/TIMs
Ephedrine, acetic anhydride, MDMA precursors, GBL
Tested For Explosives
Urea nitrate, ammonium nitrate, TATP, peroxide, chlorate, bromate, perchlorate
Tested For Narcotics
Cocaine, heroin, marijuana, LSD, synthetic cannabinoids and cathinones, ecstasy, methamphetamine, amphetamine, ketamine, GHB, barbituates, flunitrazepam, morphine, PCP, mandrax, mephedrone, fentanyl, paracetamol, methadone
Sample Introduction
Liquid;Solid;
False Positive Rates
1%
False Negative Rates
1%
Start Up Time (From Cold Start To Sample Ready)
Immediate
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Immediate
Alarm Capability
Visual color change
Training Required
<1 hour training
Manuals Available
Yes
Warranties
3 year
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: