iXR Raman Spectrometer
The Thermo Scientific™ iXR Raman Spectrometer offers performance comparable to laboratory research grade Raman spectrometers, and it is suitable for demanding research, product development, and manufacturing needs. It is made specifically for hyphenated techniques. Configurable excitation laser wavelengths and spectral resolution allow for maximizing the performance of particular materials. The iXR Raman spectrometer can be coupled with rheology, hot melt extrusion, lab and manufacturing scale processing equipment.
Availability: Commercially Available
| Manufacturer |
| Thermo Fisher Scientific, Inc. |
| Product Name |
| iXR Raman Spectrometer |
| Detection Category |
| Chemical; Explosives |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Raman Spectroscopy; |
| Application |
| Bulk Analysis; Laboratory Analysis; |
| Product Model Number |
| IQLAADGABFFAHCMBJH |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The Thermo Scientific™ iXR Raman Spectrometer offers performance comparable to laboratory research grade Raman spectrometers, and it is suitable for demanding research, product development, and manufacturing needs. It is made specifically for hyphenated techniques. Configurable excitation laser wavelengths and spectral resolution allow for maximizing the performance of particular materials. The iXR Raman spectrometer can be coupled with rheology, hot melt extrusion, lab and manufacturing scale processing equipment. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| Market Entry Date |
| 2017 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Supporting Documentation |
| Docs: Thermo - iXR Raman Spectrometer.pdf; |
| Dimensions |
| 14.6 x 11.4 x 17.3 in (37 x 29 x 44 cm) |
| Weight |
| >50 Lbs.; 55 Lbs. (25 kg) |
| Power Requirements |
| AC/DC Line Power; 100-240 VAC 47-63 Hz |
| Transportability |
| Benchtop/Fixed |
| Ruggedness |
| None; Not militarized, drop sensitive |
| Operating Conditions |
| 16 to 27°C (61 to 81°F), 20 to 80% RH |
| Consumables |
| None |
| Suggested Routine Maintenance |
| Preventative maintenance performed via manufacturer |
| Data Analysis Support Equipment |
| Thermo Scientific OMNIC software suite |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Tested For Chemical Agents |
| Amenable based on technology |
| Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
| Tested For Explosives |
| Amenable based on technology |
| Tested For Narcotics |
| Amenable based on technology; fentanyl, carfentanil, sufentanil, alfentanil, remifentanil, heroin, ketamine, lorazepam, 3-quinuclidinyl benzilate, U-47700 |
| Other Chemical Targets |
| Amenable based on technology |
| Adaptability |
| Yes; user can add new targets in the field |
| Sample Introduction |
| Liquid; Solid; |
| Sensitivity/Detection Limits |
| Bulk; mg; g; % |
| Known Interferents/Inhibitors |
| Analysis of mixtures can produce erroneous search results unless the library contains a reference spectrum of the mixture itself. |
| Start Up Time (From Cold Start To Sample Ready) |
| Minutes |
| Response Time (Sample Application To Output) |
| <5 minutes; 10 seconds to a couple minutes depending on library size |
| Total Run Time |
| Minutes |
| Software Control |
| PC |
| Other Operational Parameters |
| Supported excitation lasers: 455 nm, 532 nm, 785 nm, Spectral Range (variable): 50 - 3500 cm-1, 50 - 6000 cm-1 (for extended range) |
| Training Required |
| <1 day training |
| Training Available |
| Yes. 2 hour on-site or at manufacturer facility for advanced classes. |
| Manuals Available |
| Yes |
| Reachback Service |
| Yes |
| Warranties |
| 1 year, extended warranties also available |
| IATA Shipping Restrictions |
| No |
| Data File Type Format |
| SPA, XLS |